NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 19/23650
Document / 49 pages

Water analysis results, Hillview Reservoir, Sept 2001

Machine-extracted title · confidence 50%

Laboratory report detailing metal analysis of water samples collected from Hillview Reservoir on September 26, 2001.

NYC-WTC_000026703–000026751

Folder label: “23650

Page image
Scanned page image, NYC-WTC_000026737
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

REPORT OF ANALYSIS Westchester County Department of Labs and Research 2 Dana Road Valhalla, New York

gency: New York City DEP DWQC Sample BROOKLYN Distribution Laboratory 96-05 Horace Harding Ex. Corona N.Y. 11368 Sample 24950 DEP LAB #29062 Dr. Ian Hurley ID of Source: Received LK Collection 9/25/2001 AT 8:54:00 Bottle 8747,4534,3069,0488,71 54,C008 Submitted 9/26/2001 AT 11:27:00 Collected By: KAGZI Sample Type: POT_DW Comment: PWS No.: Source Code: Type Descriptor: Sample chilled on arrival? : YES Report

Sample No. AD23654 Method Test Description Results Units MDL Analyzed on Validator bis(2-Ethylhexyl)phthalate 0.62 ug/L 0.60 10/7/2001 DLV Butachlor < MDL ug/L 0.40 10/7/2001 DLV EPTC <MDL ug/L 1.0 10/7/2001 DLV Hexachlorobenzene < MDL ug/L 0.10 10/7/2001 DLV Hexachlorocyclopentadiene < MDL ug/L 0.10 10/7/2001 DLV Metolachlor < MDL ug/L 0.75 10/7/2001 DLV Metribuzin <MDL ug/L 0.15 10/7/2001 DLV Molinate <MDL ug/L 0.90 10/7/2001 DLV Simazine <MDL ug/L 0.40 10/7/2001 DLV Terbacil < MDL ug/L 2.0 10/7/2001 DLV Recoveries for four of the eighteen compounds in the MDL Standard were outside of their acceptance ranges. Recoveries for three of the eighteen compounds in the LCS Standard were outside of their acceptance ranges. Recoveries for four and three of the eighteen compounds in the Spiked Sample and the Spiked Duplicate Sample respectively, were outside of their acceptance ranges. The level for bis(2-Ethylhexyl)phthalate in the Laboratory GCMS Scan For Unknowns Other unknown compounds ug/L 10/16/2001 DLV A scan of the extract prepared for the 508 analysis, from 35-550 amu using a mass spectrometer, does not reveal the presence of non-target compounds. Stat charge for VOLATILE organic Completed 9/26/2001 12:04 AM SV

Approved Pam Dilsizian QA Officer Date Approved: 11/5/2001

Environmental Laboratories emailed Original 11/5/2001

NYS ELAP # 10108 Page 7 of 7

NYC-WTC_000026737

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000026737Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000026695 · Box DEP Box 19

Westchester County Department of Labs and Research chain of custody form for environmental samples submitted by the City DEP.

Filed in the same folder

NYC-WTC_000026619 · Box DEP Box 19

Laboratory report detailing inorganic contaminant analysis of water samples collected from Hillview Reservoir on September 25, 2001.

Similar indexed content

Compare copies and versions →