SEP-25-2001 12:31 LABS & RESEARCH 1 914 231 1772 P.14
!
I
REPORT OF ANALYSIS
Westchester County Department of Labs and Research 2 Dana Road Valhalla, New York 10595
Agency: New York City DEP DWQC Sample Location: HILLVIEW RESERVOIR
Distribution Laboratory
i
96-05 Horace Harding Ex. 8th I
i
Corona N.Y. 11368 Sample Point BX3
Dr. Ian Hurley ID of Source:
Received By: SV Collection Date: 9/14/2001 AT 8:48:00 A
Bottle No.: 27879 Submitted On: 9/14/2001 AT 1:38:00 P
Collected By: AS Sample Type: POT_DW
Comment: PWSNo.: Source Code:
Type Descriptor:
Sample chiliad on arrival?: Y I
Report To:
I
Sample No. AD22490
Method Test Descriptton Results Unite MDL Analyzed on Valldator
Benzo(a)pyrene <MDL ug/L 0.20 9/18/2001 DLV
bis(2-Ethyhexyi)adipate <MDL ug/L 0.60 9/18/2001 DLV
bls(2-Ethylhexyl)phthalate 0.68 ug/L 0.60 9/18/2001 DLV
Butachlor <MDL ug/L 0.40 9/18/2001 DLV
EPTC <MDL ug/L 1.0 9/18/2001 DLV
Hexachlorobenzene <MDL ug/L 0.10 9/18/2001 DLV
Hexachlorocyclopentadiene <MDL ug/L 0.10 9/18/2001 DLV
Metolachior <MDL ug/L 0.75 9/18/2001 D.V
Metribuzin <MDL ug/L 0.15 9/18/2001 DLV
Molinate < MDL ug/L 0.90 9/18/2001 DLV
Simazine <MDL ug/L 0.07 9/18/2001 DLV
Terbacil <MDL ug/L 2.0 9/18/2001 dLv
Bis(2-Ethylhexyl)phthalate was present in the Laboratory Blank at 0.37 ug/L. The recovery for bis(2-Ethylhexy)phthalate in
the MDL Standard was above its acceptance range. The recoveries for Terbacil in the LCS Standard and the Spiked i
Sample were above their acceptance ranges. The recovery for one of the three Surrogate Standards in this sample was!
above its acceptance range. This sample was submitted to our laboratory using NYCDEP bottles. i
GC/MS Scan For Unknowns
other unknown compounds 9/24/2001 Div
A scan of the extract prepared for the 508 analysis, from 35-550 amu using a mass spectrometer. does not reveal the
presence of any non-target compounds. I
I
Approved By: Pam Dilsizian QA Officer Date Approved: 9/25/2001
Environmental Laboratories
NYS ELAP # 10108 Copy 9/26/2001
(914) 593-5575 i
Page 2 of 2
1
TRTO D 1/
NYC-WTC_000025760
OCR can misread numbers and units. Confirm readings against the page image before using them.