NYC-WTC_000024762
Laboratory report of GCMS calibration data for sample AE10241 conducted between May 14 and May 16, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Laboratory report of GCMS reference standard analysis showing response values for 15 volatile organic compounds on May 17-21, 2002.
NYC-WTC_000025512–000025519Folder label: “GCMS X 5/17/02 A 5/16/02”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
€
Jser: Nefliu, Marcela Vestchester Dept, of Labs & Research Jate: 05/28/2002 Time: 14:31:05 Jample: AE10812 Analysis: $REGCMS Reference for GCMS Scan Jnits: ug Jtarted: 5/17/02 13:47 Ended: 5/21/02 13:47 Analyst MN Result source: manual entry ’age: 1
Component Name 1 Viol Result ■ Qualifier MDL 1 1 n-Nitrosodimethylamine 6.3 2.0 2 bis(2-Chloroethyl)ether 17 2.0 3 1,3-Dichlorobenzene 15 2.0 4 1,4-Dichlorobenzene 14 _______ 2.0 5 1,2-Dichlorobenzene 16 2.0 6 2,2-oxybis(1-Chloropropane) 18 2.0 7 n-Nitrosodi-n-propylamine 18 _______ 2.0 8 Hexachloroethane 11 2.0 9 Nitrobenzene 17 2.0 10 .Isophorone 19 2.0 11 .bis(2-Chloroethoxy)methane 17 _______ 2.0 12 1,2,4-Trichlorobenzene 15 2.0 13 Naphthalene 18 2.0 14 Hexachlorobutadiene 12 2.0 15 2-Chloronaphthalene 19 _______ 2.0 16 Dimethylphthalate 18 2.0 17 2,6-Dinitrotoluene 19 2.0 18 Acenaphthylene 16 _______ 2.0 19 Acenaphthene 18 2.0 20 2,4-Dinitrotoluene 17 2.0 21 Diethylphthalate 20 2.0 22 4-Chlorophenylphenylether 18 2.0 23 । Fluorene 18 2.0 24 Azobenzene 17 2.0 25 n-Nitrosodiphenylamine 18 _______ 2.0 26 4-Bromophenylphenylether 18 2.0 27 ‘Hexachlorobenzene 18 2.0 28 Phenanthrene 18 2.0 29 Anthracene 16 2.0 30 Di-n-butylphthalate 19 2.0 31 I Fluoranthene 18 2.0 32 | Pyrene 20 2.0 33 Butylbenzylphthalate 18 _______ 2.0 34 Benzo(a)anthracene 18 2.0 35 ,bis(2-Ethylhexyl)phthalate 18 2.0 36 Chrysene 19 2.0 37 Di-n-octylphthalate 16 2.0 38 ' Benzo(b)fluoranthene 18 2.0 39 . Benzo(k)fluoranthene 18 2.0 40 Benzo(a)pyrene 13 _______ 2.0 41 lndeno(1,2,3-cd)pyrene 12 2.0 42 Dibenz(a,h)anthracene 15 2.0 43 Benzo(g,h,i)perylene 16 2.0
NYC-WTC_000025512
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000024762
Laboratory report of GCMS calibration data for sample AE10241 conducted between May 14 and May 16, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000024644
Laboratory report displaying reference standard results for GCMS analysis of sample AE11157 conducted between May 13 and May 16, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000022508
Calibration verification report listing response factors for target compounds in sample AE11424 analyzed May 17-21, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000024441
Laboratory record of reference standard analysis for volatile organic compounds using GCMS methods from May 13 to May 15, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000024758
Laboratory report of a GCMS blank run for sample AE10241 conducted between May 14 and May 16, 2002.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000024437
Laboratory report showing calibration results for volatile organic compounds using GCMS methods between May 13 and May 15, 2002.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000024640
Laboratory report displaying calibration data for GCMS analysis of sample AE11157 conducted between May 13 and May 16, 2002.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000022504
Laboratory report showing blank test results for nitrosamines and other compounds in sample AE11424 analyzed May 17-21, 2002.
1 shared topics · Same agency, volume and box · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000025508
Laboratory report of GCMS calibration data showing response values and detection limits for 15 volatile organic compounds on May 17-21, 2002.
1 shared topics · Same agency, volume and box · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000024543
Laboratory report displaying calibration data for GCMS analysis of sample AE11282 conducted between May 13 and May 16, 2002.
1 shared topics · Same agency, volume and box · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000044111
Reference report listing expected values for organic compounds including nitrosamines and chlorobenzenes used to validate analytical results.
1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000045698
Laboratory report showing GC/MS calibration verification data for volatile organic compounds with response values in May 2002.
1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000025494
Department of Environmental Protection administrative record sheet for World Trade Center site activities dated May 2002.
Filed in the same folder
NYC-WTC_000025495
Laboratory log sheet recording Method 608 extraction parameters and sample counts for sample AE11423 in May 2002.
Filed in the same folder
NYC-WTC_000025499
Laboratory report showing non-detect levels for 15 volatile organic compounds in a GCMS method blank processed on May 17-21, 2002.
Filed in the same folder
NYC-WTC_000025508
Laboratory report of GCMS calibration data showing response values and detection limits for 15 volatile organic compounds on May 17-21, 2002.
Filed in the same folder
NYC-WTC_000025520
Laboratory report of GCMS analysis for sample AE10812 conducted on May 29, 2002, showing surrogate recovery data.
Filed in the same folder