GCMS blank analysis results for sample AE11379, May 21, 2002

Machine-extracted title · confidence 95%

Laboratory report showing GCMS blank analysis for sample AE11379 conducted on May 21, 2002, with results below minimum reporting levels.

NYC-WTC_000025054–000025071

Folder label: “GCMS X 5/15/02 A 5/17/02

Page image
Scanned page image, NYC-WTC_000025056
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Quantitation Report (QT Reviewed)

Data File : C:\MSDCHEM\l\DATA\051702\0515LB.D Vial: 16 Acq On : 18 May 2002 1:49 am Operator: Mclean Sample : 5/15 eh Inst Instrumen Mise Multiplr: 1.00 MS Integration Params: EVENTS.E Quant Time: May 20 09:53:26 2002 Quant Results File: 050102.RES

Quant Method : C:\MSDCHEM\1\METHODS\050102.M (Chemstation Integrator) Title : 508 Modified GC/MS scan Last Update : Mon May 13 11:40:29 2002 Response via : Initial Calibration DataAcq Meth : 508SCAN

Compound R.T. Qlon Response Cone Unit Qvalue

36) Fluoroanthene 0.00 202 0 N.D. 38) Pyrene 0.00 202 0 N.D. 39) Butylbenzylphthalate 0.00 149 0 N.D. 40) Benzo(a)anthracene 30.81 228 36219 N.D. 41) Bis(2-ethylhexyl)phthalate 0.00 149 0 N.D. 42) Chrysene 0.00 228 0 N.D. 44) Di-n-octylphthalate 0.00 149 0 N.D. 45) Benzo(b)fluoranthene 0.00 252 0 N.D. 46) Benzo(k)fluoranthene 0.00 252 0 N.D. 47) Benzo(a)pyrene 0.00 252 0 N.D. 48) Indeno(1,2,3-cd)pyrene 0.00 276 0 N.D. 49) Dibenz(a,h)anthracene 0.00 278 0 N.D. 50) Benzo(g,h,i)perylene 0.00 276 0 N.D.

(#) = qualifier out of range (m) = manual integration (+) = signals summed 0515LB.D 050102.M Tue May 21 11:57:54 2 0 02 Page 2

NYC-WTC_000025056

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000025056Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →