NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 18/GCMS X 5/9/02 A 5/20/02
Document / 22 pages

GCMS instrument log for sample AE09676, May 2002

Machine-extracted title · confidence 95%

Instrument log and analysis summary for GCMS testing of sample AE09676 conducted on May 23, 2002.

NYC-WTC_000023789–000023810

Folder label: “GCMS X 5/9/02 A 5/20/02

Page image
Scanned page image, NYC-WTC_000023792
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document Quantitation Report (QT Reviewed) Data File : C:\HPCHEM\l\DATA\MAY2002\9676.D Vial: 10 Acq On : 20 May 2002 4:02 pm Operator: Sample : EXTRACTED 5/9 Inst : 209 Mise Multiplr: 1.00 MS Integration Params: GOOFY.P Quant Time: May 21 11:26 2002 Quant Results File: GCMS0520.RES Quant Method : C:\HPCHEM\1\METHODS\GCMS0520.M (RTE Integrator) Title : 209 625/TCLP calibration table Last Update : Mon May 20 15:10:30 2002 Response via : Initial Calibration DataAcq Meth : GCMS0520

Compound R.T. Qlon Response Cone Unit Qvalue 35) Anthracene 25.52 178 187 N.D. 36) Di-n-butylphthalate 27.50 149 12156 0.43 ug/1 # 98 37) Fluoranthene 0.00 202 0 N.D. 3 9) Pyrene 0.00 202 0 N.D. 40) Butylbenzylphthalate 0.00 149 0 N.D. 41) Benzo(a)anthracene 33.57 228 1279 N.D. 42) Bis(2-ethylhexyl)phthalate 33.81 149 1422 N.D. 43) Chrysene 33.65 228 580 N.D. 45) Di-n-Octylphthalate 35.55 149 177 N.D. 46) Benzo(b)fluoranthene 36.63 252 512 N.D. 47) Benzo(k)fluoranthene 36.69 252 1818 N.D. 48) Benzo(a)pyrene 37.60 252 301 N.D. 49) Indeno(1,2,3-cd)pyrene 0.00 276 0 N.D. 50) Dibenz(a,h)anthracene 0.00 278 0 N.D. 51) Benzo(g,h,i)perylene 0.00 276 0 N.D.

(#) = qualifier out of range (m) = manual integration 9676.D GCMS0520.M Tue May 21 11:26:51 2002 Page 2

NYC-WTC_000023792

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000023792Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →