NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 18/GCMS X 5/9/02 A 5/10/02
Document / 9 pages

GC/MS analysis results, sample AE09764, May 15 2002

Machine-extracted title · confidence 100%

Laboratory report page showing GC/MS analysis for sample AE09764 including surrogate recovery data on May 15, 2002.

NYC-WTC_000023594–000023602

Folder label: “GCMS X 5/9/02 A 5/10/02

Page image
Scanned page image, NYC-WTC_000023597
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Quantitation Report (QT Reviewed)

Data File : C:\HPCHEM\l\DATA\MAY1002\9764.D Vial: 9 Acq On : 10 May 2002 8:52 pm Operator: Sample : GC/MS SCAN 5/9 Inst : 209 Mise Multiplr: 1.00 MS Integration Params: GOOFY.P Quant Time: May 13 10:08 2002 Quant Results File: GCMS0510.RES

Quant Method : C:\HPCHEM\1\METHODS\GCMS0510.M (RTE Integrator) Title : 209 625/TCLP calibration table Last Update : Mon May 13 08:58:06 2002 Response via : Initial Calibration DataAcq Meth : GCMS0510

Compound R.T. Qlon Response Cone Unit Qvalue

35) Anthracene 25.74 178 6978 N.D. 36) Di-n-butylphthalate 27.52 149 36311 0.81 ug/1 99 37) Fluoranthene 29.24 202 4822 N.D. 39) Pyrene 29.91 202 4684 N.D. 40) Butylbenzylphthalate 32.05 149 101 N.D. 41) Benzo(a)anthracene 33.61 228 2820 N.D. 42) Bis(2-ethylhexyl)phthalate 33.84 149 3111 N.D. 43) Chrysene 33.68 228 1268 N.D. 45) Di-n-Octylphthalate 0.00 149 0 N.D. 46) Benzo(b)fluoranthene 36.71 252 525 N.D. 47) Benzo(k)fluoranthene 36.71 252 525 N.D. 48) Benzo(a)pyrene 37.83 252 2219 N.D. 49) Indeno(1,2,3-cd)pyrene 0.00 276 0 N.D. 50) Dibenz(a,h)anthracene 0.00 278 0 N.D. 51) Benzo(g,h,i)perylene 0.00 276 0 N.D.

(#) = qualifier out of range (m) = manual integration 9764.D GCMS0510.M Mon May 13 10:11:35 2002 Page 2

NYC-WTC_000023597

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000023597Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →