NYC-WTC_000045202
Calibration data report for gas chromatography mass spectrometry analysis of sample AE10431 conducted in May 2002.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗Laboratory report of gas chromatography mass spectrometry calibration data for volatile organic compounds conducted on May 9, 2002.
NYC-WTC_000023216–000023219Folder label: “GCMS X 5/8/02 A 5/9/02”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Data File C:\HPCHEM\1\DATA\MAY0902\CAL80.D Vial: 2 Acq On 9 May 2002 3 :16 pm Operator: Sample Inst : 209 Mise Multiplr: 1.00 MS Integration Params: GOOFY.P Quant Time: May 10 10:10 2002 Quant Results File: GCMS0507.RES
Method : C:\HPCHEM\1\METHODS\GCMS0507.M (RTE Integrator) Title : 209 625/TCLP calibration table Last Update : Fri May 10 09:50:49 2002 Response via : Initial Calibration Abundance TIC: CAL80.D 44000004
4200000 1E 2 § 4000000 I8 3800000 o
3600000 5 2 3400000 2 2 gg J 2o 85 t 8 t S 8 3200000 z8 28 8 tg 1 9§ Co
3000000 g £ Q 6 £e 2 o . fs 2800000 i8 I8 2 2 2 ( o
11 e s 8 8 Iw 2600000 ig 9 5 5 1 1 tD o til h s f8 1 2400000 <1 i- 46 6 2200000 s8 85 898* Ec ■
) $ 2c . 64. if 1 89 J: 58§8:: § m s o 2 g h £ 2000000 zf 1800000 2 | ll 8 s2
8 i 3
5 Is 1 11 t o o > o 1600000 t § It i if 2 Q
1 Ia 1400000
1200000 ! I x N+ £
1000000 z E
I O I 800000 <) 600000 (
400000
200000
Time-> AN 0 . n p , . , । . 4 Ml/Hrr 4 U MMAMMMAal u n . n* J— . H i II— — rr# . . — । । , i 6.00 8.00 10.0012.0014.0016.0018.00 20.00 22.00 24.00 26.00 28.00 30.00 32.00 34.00 36.00 38.00 40.00 42.00 44.00 46.00
CAL80.D GCMS0507.M Fri May 10 10:10:48 2002 Page 3
NYC-WTC_000023219
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000045202
Calibration data report for gas chromatography mass spectrometry analysis of sample AE10431 conducted in May 2002.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000043832
Calibration data report for sample AE09681 listing response factors and concentrations for target analytes in May 2002.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000043046
Four-page document containing GCMS calibration data and response factors for various chemical compounds analyzed on May 1, 2002.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000044792
Calibration run records for gas chromatography-mass spectrometry analysis of volatile organic compounds in water samples.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000045411
GCMS calibration report for sample AE09447 showing recovery percentages for various compounds from May 8, 2002.
1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000043564
Report detailing the response values for GC/MS reference standards used to verify instrument performance on May 6, 2002.
1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000046226
Laboratory report of GCMS calibration analysis for sample AE09579 conducted on May 8, 2002, listing detection limits.
1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000044766
Calibration run records for gas chromatography-mass spectrometry analysis of volatile organic compounds in water samples.
1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000043050
Eight-page laboratory report showing GCMS reference analysis results for volatile organic compounds analyzed on May 1, 2002.
1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000043174
Laboratory report for DEP Box 25 showing GCMS calibration results for sample AE09450 with response factors and MDLs from May 2002.
1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000045206
Laboratory record containing manual entry reference values for volatile organic compounds in environmental sample AE10431 from May 11, 2002.
1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000043560
Calibration report listing target compounds and their concentrations for the GC/MS analysis performed on May 6, 2002.
1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000022961
Department of Environmental Protection administrative record sheet for World Trade Center site activities dated May 2002.
Filed in the same folder
NYC-WTC_000022962
Fragmentary record containing a document identifier and date from the DEP GCMS analysis series.
Filed in the same folder
NYC-WTC_000022965
Laboratory report of a GCMS blank run conducted on May 14, 2002, showing non-detect results for various compounds.
Filed in the same folder
NYC-WTC_000022990
Laboratory report documenting GCMS calibration verification analysis conducted on May 14, 2002.
Filed in the same folder
NYC-WTC_000022994
Laboratory report of GCMS reference standard analysis conducted on May 14, 2002, showing recovery percentages.
Filed in the same folder