NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 18/GCMS X 5/8/02 A 5/10/02
Document / 7 pages

GCMS calibration table review, April 2002

Machine-extracted title · confidence 100%

Reviewed data file listing retention times and response factors for deuterated internal standards.

NYC-WTC_000022812–000022818

Folder label: “GCMS X 5/8/02 A 5/10/02

Page image
Scanned page image, NYC-WTC_000022813
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Quantitation Report (QT Reviewed) Data File C:\HPCHEM\1\DATA\MAY0 3 02\9151.D Vial: 30 Acq On 4 May 2002 8:27 pm Operator: Sample RE-EXT. Inst : 209 Mise Multiplr: 1.00 MS Integration Params: GOOFY.P Quant Time: May 7 11:46 2002 Quant Results File: GCMS0501.RES Quant Method : C:\HPCHEM\1\METHODS\GCMS0501.M (RTE Integrator) Title : 209 625/TCLP calibration table Last Update : Wed May 01 10:40:31 2002 Response via : Initial Calibration DataAcq Meth : GCMS0501

Compound R.T. Qlon Response Cone Unit Qvalue 35) Anthracene 25.57 178 350 N.D. 36) Di-n-butylphthalate 27.54 149 2918 N.D. 37) Fluoranthene 0.00 202 0 N.D. 3 9) Pyrene 0.00 202 0 N.D. 40) Butylbenzylphthalate 32.07 149 440 N.D. 41) Benzo(a)anthracene 33.64 228 2658 N.D. 42) Bis(2-ethylhexyl)phthalate 33.86 149 61556 3.10 ug/1 99 43) Chrysene 33.70 228 882 N.D. 45) Di-n-Octylphthalate 35.60 149 224 N.D. 46) Benzo(b)fluoranthene 36.69 252 200 N.D. 47) Benzo(k)fluoranthene 36.77 252 427 N.D. 48) Benzo(a)pyrene 37.86 252 2329 N.D. 49) Indeno(1,2,3-cd)pyrene 0.00 276 0 N.D. 50) Dibenz(a,h)anthracene 0.00 278 0 N.D. 51) Benzo(g,h,i)perylene 0.00 276 0 N.D.

(#) = qualifier out of range (m) = manual integration 9151.D GCMS0501.M Tue May 07 11:46:51 2002 Page 2

NYC-WTC_000022813

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000022813Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →