NYC 9/11 Public Portal Document
Quantitation Report (QT Reviewed)
Data File : C:\HPCHEM\1\DATA\FEB1402\31248.D Vial: 27
Acq On : 15 Feb 2002 4:25 am Operator: 209 GALOS
Sample : GC/MS SCAN 2/11 Inst : GC/MS 209
Mise : Multiplr: 1.00
MS Integration Params: GOOFY.P
Quant Time: Feb 15 11:59 2002 Quant Results File: GCMS0208.RES
Quant Method : C:\HPCHEM\1\METHODS\GCMS0208.M (RTE Integrator)
Title : 209 625/TCLP calibration table
Last Update : Wed Feb 13 11:43:23 2002
Response via : Initial Calibration
DataAcq Meth : GCMS0208
Internal Standards R.T. Qlon Response Cone Units Dev(Min)
1) 1,4“Dichlorobenzene-d4 12.35 152 360431 20.00 ug/1 0.00
10) Naphthalene-dS 15.98 136 1407009 20.00 ug/1 -0.02
17) Acenaphthene-dlO 21.30 164 756557 20.00 ug/1 -0.02
29) Phenanthrene-diO 25.75 188 1117789 20.00 ug/1 -0.02
38) Chrysene-dl2 33.82 240 796250 20.00 ug/1 -0.02
44) Perylene-dl2 38.11 264 520709 20.00 ug/1 -0.02
System Monitoring Compounds
37) 2,4-DDD 30.83 235 48727 4.34 ug/mL 0.33
Spiked Amount 5.000 Recovery = 86.80%
Target Compounds Qvalue
2) N-nitroso-dimethyl amine 0.00 74 0 N.D.
3) bis(2-Chloroethyl)ether 0.00 93 0 N.D.
4) 1,3-Dichlorobenzene 0.00 146 0 N.D.
5) 1,4-Dichlorobenzene 0.00 146 0 N.D.
6) 1,2-Dichlorobenzene 0.00 146 0 N.D.
7) 2,2’-oxybis(1-Chloropropan 0.00 45 0 N.D.
8) N-Nitroso-di-n-propylamine 0.00 70 0 N.D.
9) Hexachloroethane 0.00 117 0 N.D.
11) Nitrobenzene 0.00 77 0 N.D.
12) Isophorone 0.00 82 0 N.D.
13) bis(2-Chloroethoxy)methane 0.00 93 0 N.D.
14) 1,2,4-Trichlorobenzene 0.00 180 0 N.D.
15) Naphthalene 16.05 128 498 N.D.
16) Hexachlorobutadiene 0.00 225 0 N.D.
18) Hexachlorocyclopentadiene 0.00 237 0 N.D.
19) 2-Chloronaphthalene 0.00 162 0 N.D.
20) Dimethylphthalate 0.00 163 0 N.D.
21) 2,6-Dinitrotoluene 0.00 165 0 N.D.
22) Acenaphthylene 0.00 152 0 N.D.
23) Acenaphthene 0.00 153 0 N.D.
24) 2,4-Dinitrotoluene 0.00 165 0 N.D.
25) Diethylphthalate 22.79 149 200 N.D.
26) 4-Chlorophenyl-phenylether 0.00 204 0 N.D.
27) Fluorene 0.00 166 0 N.D.
2 8) Azobenzen/ 1,2-Diphenylhyd 0.00 77 0 N.D.
(#) = qualifier out of range (m) = manual integration
31248.D GCMS0208.M Fri Feb 15 12:00:42 2002 Page 1
NYC-WTC_000016401
OCR can misread numbers and units. Confirm readings against the page image before using them.