NYC-WTC_000016681
Method blank report confirming absence of contamination during volatile organic compound testing procedures in January 2002.
Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗Laboratory blank report confirming no detectable contamination for nitrosamines and chlorinated solvents during the run.
NYC-WTC_000016078–000016086Folder label: “GCMS X 12/26/01 A 1/15-1/16/02”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
User: Galos, Marie Westchester Dept. of Labs & Research Date: 02/05/2002 Time: 11:39:58
Sample: AD31339 Analysis: $B1GCMS Blank for GCMS Scan Units: ug Started: 2/5/02 11:34 Ended: 2/5/02 11:34 Analyst: MG Result source: manual entry Page: 1
1 Component Name Viol oResult Qualifier MDL 1 n Nitrosodimethylamine < MDL z.u -Chloroethyl)ether <MDL ............ 2.0 <MDL 3 1.3 Dichlorobenzene ...........2.0 4 1 1 - Dichlorobenzene <MDL 2.0 5 ‘ 2 Dichlorobenzene < MDL ............ 2.0 2.0 oxybis( 1 -Chloropropane) <MDL 2.0 rosodi-n-propylamine < MDL 2.0 ■ hloroethane < MDL benzene < MDL . 2.0.. orone <MDL. ........ 2.0.. -Chloroethoxy)methane <MDL ........ 2.0 Trichlorobenzene <MDL ... 2.0 13 Nanthalene <MDL .. 2.0 14 Hexachlorobutadiene <MDL. 2.0 15 ? Chloronaphthalene _ <M DL — 2.0 <MDL thylphthalate .. 2.0 ■ ' Jinitrotoluene < MDL <MDL ....... 2.0 18 Acenaphthylene 2.0.. iaphthene < MDL 2.0 <MDL 2.0 20 2 1 Dinitrotoluene <MDL ylphthalate 2.0 rophenylphenylether < MDL 2.0 23 i iuorene < MDL 2.0 2.0 24 Azobenzene/1,2-Diphenylhydraz < MDL <MDL -..... .. 2.0 ’ 25 n Nitrosodiphenylamine 26 4-Bromophenylphenylether <MDL .. 2.0 ichlorobenzene < MDL <MDL 2.0 2.0 ianthrene racene <MDL .. 2.0 30 Dr n butylphthalate <MDL 2.0 anthene <MDL .. 2.0 2.0 ne < MDL - 2.0 33 Butylbenzylphthalate < MDL .. 34 Benzo(a)anthracene <MDL ~ 2.0 -Ethyihexyl)phthalate <MDL <MDL ........ 2.0 36 Chrysene 2.0 37 Di n octylphthalate <MDL -. 2.0 2.0 o(b)fluoranthene < MDL o(k)fluoranthene <MDL . .... 2.0 o(a)pyrene <MDL 2.0 10(1,2,3-cd)pyrene <MDL 2.0 z (a, h)a nth racene <<MDL MDL 2.0 43 Ben.zo(g,h,i)perylene . 2.00
NYC-WTC_000016078
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000016681
Method blank report confirming absence of contamination during volatile organic compound testing procedures in January 2002.
Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000016555
Blank analysis report for DEP sample AD31432 showing non-detect levels for volatile organic compounds from January 22, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000016285
Laboratory report of a GCMS blank run performed on February 7, 2002, to verify absence of contamination.
Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000016506
Blank analysis report for DEP sample AD31363 showing non-detect levels for volatile organic compounds from February 7, 2002.
Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000016242
Laboratory report of a GCMS blank run for sample AD31347 performed on February 5, 2002.
1 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000050079
Blank analysis report for GCMS testing of sample AE00005 showing non-detectable levels of target compounds.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035563
GCMS analysis results for sample AD28903 dated December 15, 2001, showing non-detect levels for various compounds.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000009428
Laboratory data table recording drip rates and volumes for GCMS Method 508 analysis.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000005159
Blank sample analysis report confirming no contamination above method detection limits for target compounds analyzed on February 1, 2002.
Similar document embedding; no shared entity or topic indexed. · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000052790
GC/MS blank analysis report for sample AE01041 showing volatile organic compound results generated on February 20, 2002.
1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000036044
Technical form recording method parameters, drip rates, and analytical data for GCMS testing procedures.
1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000005619
Blank analysis report for DEP sample AE02966 showing all target compounds below minimum detection limits.
Similar document embedding; no shared entity or topic indexed. · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000016055
DEP GCMS analysis log covering samples processed between late December 2001 and mid-January 2002.
Filed in the same folder
NYC-WTC_000016056
Technical log detailing extraction rates, volumes, and pH settings used during sample preparation for GCMS analysis.
Filed in the same folder
NYC-WTC_000016058
Documentation of instrument settings and calibration parameters for Method 508 analysis conducted in early 2002.
Filed in the same folder
NYC-WTC_000016061
Calibration data sheet listing response factors for various organic compounds including nitrosamines and chlorinated benzenes.
Filed in the same folder
NYC-WTC_000016065
Calibration report showing retention times and response factors for deuterated internal standards used in PAH analysis.
Filed in the same folder