NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 15/GCMS X 5/29/02 A 5/31/02
Document / 9 pages

GCMS analysis results for sample AE12577, June 2002

Machine-extracted title · confidence 95%

Laboratory report documenting gas chromatography-mass spectrometry analysis of environmental sample AE12577 conducted on June 6, 2002.

NYC-WTC_000014934–000014942

Folder label: “GCMS X 5/29/02 A 5/31/02

Page image
Scanned page image, NYC-WTC_000014937
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document Quantitation Report (QT Reviewed)

Data File : C:\HPCHEM\1\DATA\MAY3102\12577.D Vial: 11 Acq On : 31 May 2002 9:50 pm Operator: Morgan Sample : gc/ms scan 5/29 fb Inst : 209 Mise Multiplr: 1.00 MS Integration Params: GOOFY.P Quant Time: Jun 3 9:32 2002 Quant Results File :,GCMS0531. RES *es Quant Method : C:\HPCHEM\1\METHODS\GCMS0531.M (RTE Integrator) Title : 209 625/TCLP calibration table Last Update : Fri May 31 09:43:55 2002 Response via : Initial Calibration DataAcq Meth : GCMS0531

Compound R.T. Qlon Response Cone Unit Qvalue 35) Anthracene 25.42 178 420 N.D. 36) Di-n-butylphthalate 27.41 149 2943 N.D. 3 7) Fluoranthene 0.00 202 0 N.D. 39) Pyrene 0.00 202 0 N.D. 4 0) Butylbenzylphthalate 0.00 149 0 N.D. 41) Benzo(a)anthracene 33.48 228 2108 N.D. 42) Bis(2-ethylhexyl)phthalate 33.71 149 828 N.D. 43) Chrysene 33.48 228 2108 N.D. 45) Di-n-Octylphthalate 0.00 149 0 N.D. 4 6) Benzo(b)fluoranthene 0.00 252 0 N.D. 47) Benzo(k)fluoranthene 0.00 252 0 N.D. 48) Benzo(a)pyrene 37.65 252 2388 N.D. 4 9) Indeno(1,2,3-cd)pyrene 0.00 276 0 N.D. 50) Dibenz(a,h)anthracene 0.00 278 0 N.D. 51) Benzo(g,h,i)perylene 0.00 276 0 N.D.

(#) = qualifier out of range (m) = manual integration 12577.D GCMS0531.M Mon Jun 03 09:32:35 2002 Page 2

NYC-WTC_000014937

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000014937Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →