GCMS analysis results, Feb 27 2002

Machine-extracted title · confidence 90%

Gas chromatography-mass spectrometry results for sample AE01138 identifying unknown compounds and surrogates on February 27, 2002.

NYC-WTC_000003463–000003482

Folder label: “GCMS X 1/20/02 A 2/25/02

Page image
Scanned page image, NYC-WTC_000003465
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document i V LSwEU)

Data File : C: \MSDCHEM\1\5973N\02FEB25\01138.D Vial: 4 Acq On : 25 Feb 2002 1:43 pm Operator: Sample : 508 scan Inst : Instrumen Mise : February 2 5, 2002 Multiplr: 1.00 MS Integration Params: SPLIT.P Quant Time: Feb 26 08:28:35 2002 Quant Results File: HP022102.RES Quant Method : C:\MSDCHEM\1...\HP022102.M (RTE Integrator) Title : 508 scan method Last Update : Mon Feb 25 10:47:59 2002 Response via : Initial Calibration DataAcq Meth : HP020702

Internal Standards R.T. Qlon Response Cone Units Dev(Min) 1) 1,4-Dichlorobenzene-d4 9.72 152 1379232 20.00 ug/L 0.00 10) Naphthalene-d8 13.20 136 5920319 20.00 ug/L 0.00 17) Acenaphthene-diO 18.33 164 2893894 20.00 ug/L 0.00 29) Phenanthrene-diO 22.63 188 5029630 20.00 ug/L -0.01 38) Chrysene-dl2 30.49 240 3687581 20.00 ug/L -0.03 44) Perylene-dl2 34.41 264 2505094 20.00 ug/L -0.04 System Monitoring Compounds 37) 2,4-DDD 27.72 235 289010 4.31 ug/L 0.00 Spiked Amount 5.000 Recovery = 86.20% Target Compounds Qvalue 20) Dimethylphthalate 18.34 163 466043 2.65 ug/L # 58 21) 2,6-Dinitrotoluene 18.33 165 370862 9.15 ug/L +: 27

(#) = qualifier out of range (m) = manual integration 01138.D HP022102.M Tue Feb 26 08:28:36 2002 Page 1

NYC-WTC_000003465

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000003465Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →