NYC Department of Health WTC draft press release, February 2002 — page 1

DEP Hard Copies (68 Boxes) / DEP Box 42 / E-mails R. Avaltroni 2002
NYC-WTC_000160537Machine-extracted title
Memo or letter

Summary Forwarded draft press release from NYC Department of Health regarding WTC environmental and health guidance.

Asbestos is a health hazard when it is airborne; in no instance was an elevated level of asbestos found in the air samples taken from these buildings.

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, dust, fiberglass

E-mails R. Avaltroni 2002 — page 5

DEP Hard Copies (68 Boxes) / DEP Box 42 / E-mails R. Avaltroni 2002
NYC-WTC_000160626
Lab report

The air samples from inside the buildings showed no elevated levels of asbestos, however low levels of asbestos and fibrous glass were found in the settled dust in some of the residential units, common

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, debris, dust

Timeline of environmental cleaning and monitoring activities at 125 Cedar — page 2

DEP Hard Copies (68 Boxes) / DEP Box 31 / 125 CEDAR 1 OF 2
NYC-WTC_000156045Machine-extracted title
Lab report

Summary Summary document outlining key dates from June to September 2002 regarding inspections, scope development, and contract bidding.

silica) and mercury in following procedures established in the WTC Indoor Air Pre-Cleanup Pilot Study. 2) Air samples should be collected for asbestos, fibrous glass and silica.

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, dioxin, dust, lead, mercury, pahs, silica

EPA/NYC Clean Up Testing Program Plan, November 22, 2002 — page 1

DEP Hard Copies (68 Boxes) / DEP Box 05 / EPA/NYC Indoor Air/Approach Request FEMA
NYC-WTC_000141528Machine-extracted title
Form

Summary Program description detailing direct assistance and asbestos testing for residential buildings in Lower Manhattan.

b) Testing for airborne asbestos within residences or building areas.

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, debris, dust

EPA/NYC Clean Up Testing Program, May 2002 — page 1

DEP Hard Copies (68 Boxes) / DEP Box 05 / EPA/NYC Indoor Air/Approach Request FEMA
NYC-WTC_000141560Machine-extracted title
Form

Summary Program overview establishing an EPA hotline and contractor services for apartment cleaning and asbestos testing.

b) Testing for airborne asbestos within residences or building areas.

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, debris, dust

EPA/NYC Clean Up Testing Program, May 6, 2002 — page 1

DEP Hard Copies (68 Boxes) / DEP Box 05 / EPA/NYC Indoor Air/Approach Request FEMA
NYC-WTC_000141563Machine-extracted title
Form

Summary Document detailing the initiative to provide professional cleaning and air sampling assistance to residents.

b) Testing for airborne asbestos within residences or building areas.

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, debris, dust

EPA/NYC Clean Up Testing Program proposal, May 3, 2002 — page 1

DEP Hard Copies (68 Boxes) / DEP Box 05 / EPA/NYC Indoor Air/Approach Request FEMA
NYC-WTC_000141567Machine-extracted title
Form

Summary Proposal outlining direct assistance options including professional cleaning and air testing for Lower Manhattan residents.

b) Testing for airborne asbestos within residences or building areas.

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, debris, dust

Panel agenda for Air Quality After 9/11 conference, March 2004 — page 15

DEP Hard Copies (68 Boxes) / DEP Box 42 / WTC- Air Data
NYC-WTC_000161650Machine-extracted title
Form

Summary Agenda listing panelists from federal agencies, unions, and city departments for a March 2004 conference on post-9/11 air quality.

They found far more asbestos fibers than did government investigators.

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, dust

NYC DOH hotline Q&A on HVAC cleaning protocols and asbestos, — page 4

DEP Hard Copies (68 Boxes) / DEP Box 06 / DEP 59.17 Junction Blvd, 11th FL
NYC-WTC_000142733Machine-extracted title
Lab report

Summary Guidance document explaining requirements for HVAC cleaning and asbestos abatement regulations for building owners.

The Department of Environmental Protection requires an asbestos abatement if more than 1% of dust in a bulk sample contains asbestos fibers

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, debris, dust, particulate

EPA interim final report on WTC background study, April 2003 — page 147

DEP Hard Copies (68 Boxes) / DEP Box 08 / INTERIM FINAL April 2003
NYC-WTC_000146015Machine-extracted title
Chain of custody

Summary Interim final report from EPA Region 2 detailing a background study of environmental conditions at the World Trade Center site.

NIOSH Method 7400: Asbestos and Other Fibers by PCM; NIOSH Manual of Analytical Methods; U.S.

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, dust, lead, silica

Chain of custody distribution list, May 2002 — page 8

DEP Hard Copies (68 Boxes) / DEP Box 43 / E-mails 2002 M. Gilsenan
NYC-WTC_000162219Machine-extracted title
Chain of custody

Summary EPA staff distributed a chain of custody document to multiple federal and city agencies on May 15, 2002.

Three collocated samples will Asbestos ASTMD 5755-95 ASTMD 5755

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, dioxins, dust, lead, pahs, silica

NYC-WTC_000152790 — page 5

DEP Hard Copies (68 Boxes) / DEP Box 26
NYC-WTC_000152794
Lab report

a high pH, if dust has a high pH, it may be contributing to reported symptoms of ENT irritation Asbestos

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, dust, gypsum, pm10, pm2.5, silica

NYC-WTC_000152801 — page 5

DEP Hard Copies (68 Boxes) / DEP Box 26
NYC-WTC_000152805
Lab report

a high pH, if dust has a high pH, it may be contributing to reported symptoms of ENT irritation Asbestos

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, dust, gypsum, pm10, pm2.5, silica

ATSDR/DHAC recommendations for building sampling, Sept 2001 — page 5

DEP Hard Copies (68 Boxes) / DEP Box 26
NYC-WTC_000152818Machine-extracted title
Lab report

Summary Draft document outlining concepts and priorities for sampling buildings near the WTC to identify worst-case contamination scenarios.

has a high pH, if dust has a high pH, it may be contributing to reported symptoms of ENT irritation Asbestos

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, dust, gypsum, pm2.5, silica

ATSDR/DHAC protocol for ambient and surface dust sampling near WTC, — page 4

DEP Hard Copies (68 Boxes) / DEP Box 26
NYC-WTC_000152828Machine-extracted title
Chain of custody

Summary Draft protocol establishing procedures for evaluating airborne and settled dust in residential and commercial areas near the World Trade Center.

” dust I/O Determine if asbestos is present in dust Delete?

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, dust, fiberglass, gypsum, silica

WTC Vicinity Building Survey Proposal Background Study Data — page 19

DEP Hard Copies (68 Boxes) / DEP Box 10 / BACKGROUND STUDY DATA 11.13
NYC-WTC_000149917Machine-extracted title
Lab report

Summary Proposal for sampling and assessing building interiors in the vicinity of the World Trade Center site.

Environment Post Cleanup Pilot Study Sampling Matrix Silica, Asbestos

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, dioxins, dust, gypsum, lead, pahs, silica

Re-occupancy letter for 140 Broadway, Feb 2002 — page 3

DEP Hard Copies (68 Boxes) / DEP Box 37 / 140 BROADWAY; Block: 48 Lot: 1 BIN: 1001027 70 Liberty Street
NYC-WTC_000105732Machine-extracted title
Lab report

Summary A letter from an environmental firm to the DEP outlining cleaning and inspection events at 140 Broadway following September 11.

The purpose of this analysis was to determine if this dust material contained asbestos.

Volume NYC-WTC0004Agency: Environmental Protection, Dept. ofContaminants: asbestos, dust

Document identifier page, 200 Liberty Street — page 41

DEP Hard Copies (68 Boxes) / DEP Box 35 / 200 LIBERTY STREET Block: 16 Lot: 120 BIN: 1000057 1 World Financial Center
NYC-WTC_000101712Machine-extracted title
Lab report

Summary Page displaying a document identification number and reference code for records associated with 200 Liberty Street.

DC = During Cleaning NVA = No Visible Asbestos WA = Inside Work Area NADI/NA = No Asbestos Detected AQ = Alr Quafity FAT = Final Alr Test OWA = Outside Work Area 01/1102 NYC 9/11 Public Portal Document

Volume NYC-WTC0004Agency: Environmental Protection, Dept. ofContaminants: asbestos, chrysotile, dust, lead

Document identifier page, 200 Liberty Street — page 67

DEP Hard Copies (68 Boxes) / DEP Box 35 / 200 LIBERTY STREET Block: 16 Lot: 120 BIN: 1000057 1 World Financial Center
NYC-WTC_000101738Machine-extracted title
Lab report

Summary Page displaying a document identification number and reference code for records associated with 200 Liberty Street.

NVA= No Visible Asbestos NAD/NA = No Asbestos Detected FAT = Final Air Test DC = During Cleaning IWA = Inside Work Area AQ= Air Quality OWA &= Outside Work Area 01/11/02 NYC 9/11 Public Portal Document

Volume NYC-WTC0004Agency: Environmental Protection, Dept. ofContaminants: asbestos, chrysotile, dust, lead, mercury

Draft Asbestos fact sheet for public, NYC, Feb 2002 — page 2

DEP Hard Copies (68 Boxes) / DEP Box 26
NYC-WTC_000153320Machine-extracted title
Unclassified

Summary Draft informational document explaining asbestos properties and its presence in World Trade Center materials and debris.

Levels above 70 asbestos structures per square millimeter do not imply an immediate health threat.