NYC-WTC_000104555
Document identifying the site at 77 Front Street and associated block and lot numbers for environmental records.
Environmental Protection, Dept. of · Box DEP Box 36
machine-extracted · confidence 1.00 · Check page ↗1994-08-15 – 2003-12-01
machine-extracted · confidence unavailable · Check page ↗Machine extraction can misread a scan. Check the source page. Stored confidence scores are extractor outputs, not a guarantee of accuracy; regex matches currently carry 1.00.
| Month | Pages |
|---|---|
| Sep 2001 | 2 |
| Oct 2001 | 1 |
| Feb 2002 | 1 |
| Mar 2002 | 2 |
| Apr 2002 | 2 |
| May 2002 | 4 |
| Jun 2002 | 2 |
| Jul 2002 | 3 |
| Aug 2002 | 1 |
| Sep 2002 | 1 |
NYC-WTC_000104555
Document identifying the site at 77 Front Street and associated block and lot numbers for environmental records.
Environmental Protection, Dept. of · Box DEP Box 36
machine-extracted · confidence 1.00 · Check page ↗NYC-WTC_000104556
Letter from Paramount Group reporting no asbestos detected in air and bulk samples taken at 32 Front Street.
Environmental Protection, Dept. of · Box DEP Box 36
machine-extracted · confidence 1.00 · Check page ↗NYC-WTC_000104556
Letter from Paramount Group reporting no asbestos detected in air and bulk samples taken at 32 Front Street.
Environmental Protection, Dept. of · Box DEP Box 36
machine-extracted · confidence 1.00 · Check page ↗NYC-WTC_000104556
Letter from Paramount Group reporting no asbestos detected in air and bulk samples taken at 32 Front Street.
Environmental Protection, Dept. of · Box DEP Box 36
machine-extracted · confidence 1.00 · Check page ↗NYC-WTC_000129040
Record identifying multiple properties along Front, South, and Old Slip streets included in the WTC visual survey program.
Environmental Protection, Dept. of · Box DEP Box 52
machine-extracted · confidence 1.00 · Check page ↗NYC-WTC_000139912
Documentation of cleanup status for properties on Duane and Dutch Streets included in the EPA HVAC Action Plan.
Environmental Protection, Dept. of · Box DEP Box 05
machine-extracted · confidence 1.00 · Check page ↗NYC-WTC_000146129
Correspondence from NYC Corporation Counsel providing comments on excerpts of a draft EPA evaluation report regarding the WTC response.
Environmental Protection, Dept. of · Box DEP Box 08
machine-extracted · confidence 1.00 · Check page ↗NYC-WTC_000153017
Memorandum requesting portable gasoline generators to power air sampling equipment at World Trade Center disaster sites.
Environmental Protection, Dept. of · Box DEP Box 26
machine-extracted · confidence 1.00 · Check page ↗NYC-WTC_000156262
Fragmented data sheet containing numerical records likely related to building inspections or environmental monitoring.
Environmental Protection, Dept. of · Box DEP Box 31
machine-extracted · confidence 1.00 · Check page ↗NYC-WTC_000156347
Header page from a DEP document in the BUILDINGS LISTS folder showing agency and bureau information.
Environmental Protection, Dept. of · Box DEP Box 31
machine-extracted · confidence 1.00 · Check page ↗NYC-WTC_000156564
Header page for a DEP document listing buildings requiring exterior cleanup in Zone 1 as of July 29, 2002.
Environmental Protection, Dept. of · Box DEP Box 31
machine-extracted · confidence 1.00 · Check page ↗NYC-WTC_000156676
List of buildings on Albany and Ann Streets with exterior cleanup license dates ranging from January to July 2002.
Environmental Protection, Dept. of · Box DEP Box 31
machine-extracted · confidence 1.00 · Check page ↗NYC-WTC_000220271
OSHA air monitoring data for asbestos sampling at WTC locations on September 13, 2001.
Design and Construction, Dept. of · Box not recorded
machine-extracted · confidence 1.00 · Check page ↗NYC-WTC_000267444
Asbestos monitoring data for OSHA at the WTC Financial District site, 9/13–9/19/2001.
Citywide Administrative Services, Dept. of · Box not recorded
machine-extracted · confidence 1.00 · Check page ↗NYC-WTC_000267508
Asbestos sampling data across Financial District and World Trade Center areas.
Citywide Administrative Services, Dept. of · Box not recorded
machine-extracted · confidence 1.00 · Check page ↗NYC-WTC_000307615
Personal air sampling data across Financial District sites with 0.003–0.004 f/cc readings.
Environmental Protection, Dept. of · Box not recorded
machine-extracted · confidence 1.00 · Check page ↗NYC-WTC_000317731
Personal air sampling data; asbestos levels 0.003–0.004 f/cc in Financial District.
Health and Mental Hygiene, Dept. of · Box not recorded
machine-extracted · confidence 1.00 · Check page ↗NYC-WTC_000317735
EMSL lab report: fiber analysis of air samples (NIOSH 7400) for OSHA at WTC.
Health and Mental Hygiene, Dept. of · Box not recorded
machine-extracted · confidence 1.00 · Check page ↗NYC-WTC_000317735
EMSL lab report: fiber analysis of air samples (NIOSH 7400) for OSHA at WTC.
Health and Mental Hygiene, Dept. of · Box not recorded
machine-extracted · confidence 1.00 · Check page ↗NYC-WTC_000339922
WTC D4 asbestos sampling data with dates and results.
Design and Construction, Dept. of · Box not recorded
machine-extracted · confidence 1.00 · Check page ↗NYC-WTC_000340023
Personal air sampling data in Financial District; TEM/PCM results and site locations.
Design and Construction, Dept. of · Box not recorded
machine-extracted · confidence 1.00 · Check page ↗NYC-WTC_000360598
Personal air samples show 0.003-0.004 f/cc across sectors D4, C3, etc.
Design and Construction, Dept. of · Box not recorded
machine-extracted · confidence 1.00 · Check page ↗NYC-WTC_000360775
D4 sampling results with locations and fiber counts per cc.
Design and Construction, Dept. of · Box not recorded
machine-extracted · confidence 1.00 · Check page ↗NYC-WTC_000365828
Laboratory report from ATC Associates dated Sep 19, 2001, recipient Mr. [name].
Environmental Protection, Dept. of · Box not recorded
machine-extracted · confidence 1.00 · Check page ↗NYC-WTC_000365835
Internal memorandum noting bulk sample collection and results; asbestos not detected.
Environmental Protection, Dept. of · Box not recorded
machine-extracted · confidence 1.00 · Check page ↗NYC-WTC_000419693
Personal air sampling data in the Financial District with fiber concentrations per sector.
Environmental Protection, Dept. of · Box not recorded
machine-extracted · confidence 1.00 · Check page ↗NYC-WTC_000419715
Asbestos sampling results with 0.003–0.004 f/cc ranges by sector.
Environmental Protection, Dept. of · Box not recorded
machine-extracted · confidence 1.00 · Check page ↗NYC-WTC_000421541
Personal air sampling in Financial District; multiple sectors with 0.003–0.004 f/cc readings.
Environmental Protection, Dept. of · Box not recorded
machine-extracted · confidence 1.00 · Check page ↗NYC-WTC_000421546
Personal air sampling in Financial District; 0.003–0.004 f/cc readings listed.
Environmental Protection, Dept. of · Box not recorded
machine-extracted · confidence 1.00 · Check page ↗Boxes, folders and agencies this entity's source pages are filed under, largest first. Folder labels are omitted to avoid surfacing personal names.
Environmental Protection, Dept. of · Box unavailable · Folder 1 Volume NYC-WTC0009 · 7 source pages
Design and Construction, Dept. of · Box unavailable · Folder 2 Volume NYC-WTC0009 · 4 source pages
Environmental Protection, Dept. of · Box DEP Box 36 · Folder 3 Volume NYC-WTC0004 · 4 source pages
Environmental Protection, Dept. of · Box DEP Box 31 · Folder 4 Volume NYC-WTC0006 · 4 source pages
Health and Mental Hygiene, Dept. of · Box unavailable · Folder 5 Volume NYC-WTC0009 · 3 source pages
Citywide Administrative Services, Dept. of · Box unavailable · Folder 6 Volume NYC-WTC0009 · 2 source pages
Design and Construction, Dept. of · Box unavailable · Folder 7 Volume NYC-WTC0008 · 1 source page
Environmental Protection, Dept. of · Box DEP Box 52 · Folder 8 Volume NYC-WTC0004 · 1 source page
Environmental Protection, Dept. of · Box DEP Box 05 · Folder 9 Volume NYC-WTC0006 · 1 source page
Environmental Protection, Dept. of · Box DEP Box 08 · Folder 10 Volume NYC-WTC0006 · 1 source page
Environmental Protection, Dept. of · Box DEP Box 26 · Folder 11 Volume NYC-WTC0006 · 1 source page