NYC 9/11 Public Portal Document
DRAFT
Particulate monitoring (PM 2.5)
Agency Date Location N samples N above Max (of Comment
(continuous threshold * 24 hour
monitoring) averages)
NYSDEC 9/24/01 Fresh Kills Landfill I (24 0 302
hour
average)
9/24/01 Schools and neighborhoods 10 (24 hour 0 34.3
distant from controlled zone averages)
* Proposed National Ambient Air Quality Standard is 65 ug/m3 maximum for a 24 hour period and 15 ug/m3 annual arithmetic mean.
Interpretation: No immediate public or occupational health threat.
Other Monitoring
Hudson river and water runoff from site: As reported by EPA Sunday Sept 24: ambient results to date show no observed effects due to the WTC
disaster. Samples collected in the vicinity of the WTC are generally diluted relative to the up-river sample. The East River sample results are similar
to those from the Hudson River background location.
Sediment results: As reported in EPA’s Sunday Sept 24 Dredge Material Sediment Sampling Summary, dioxin and furan (TCDD/TCDF) samples
collected on Sept. 15 (recently rec’d) greatly exceed HARS disposal criteria. The material is being disposed of in the Newark Bay Borrow Pits,
o which is designed to accommodate dredge material. PCBs (aroclors) detected in the dredge sample were weathered suggesting a relatively old
H
source.
S