Summary of Asbestos Sampling Results Page 2 of 2
Address: 333 Pearl St.
Date sampled: Nov 20, 2001
Air samples
Airborne fibers as determined by Phased Contrast Microscopy (PCM): An air sample is
collected by pulling air through a filter. The filter catches fibers and is then sent to a laboratory
to determine what types of fibers were in the air. Phase contrast microscopy identifies fibers
based on size and shape, but not mineral composition. Therefore, the fibers seen by PCM
include asbestos fibers as well as other fibers, such as textiles, fiberglass, cellulose, which might
be present in your home. By counting all fibers, we are being more protective of your health
when we compare this to our screening value for asbestos fibers.
4rea Sampled Outside Common Residence 1 Residence 2
Sample Numbers___________ A-0-12 A-C-12 A-Rl-12 A-R2-12
Concentration of Fibers in Air <.001 <.001 .001 <.001
A.t this location
Concentration of Fibers in Air at <.001 <.001 to .003 <.001 to .003 <.001 to .003
jackground locations
Screening Value** 01 f/cc 01 f/cc 01 f/cc 01 f/cc
**Screening Value - The NYC standard for asbestos in community and residential buildings is
0.01 fibers/cubic centimeter (f/cc) in indoor air. This standard is used for re-occupancy in an
indoor area where asbestos was detected and removed.