DRAFT 2/5/03 have served as a third party project monitor on at least 25 asbestos abatement projects. The Project Monitor must have performed final clearance inspections on at least 25 asbestos abatement projects. A single individual with Asbestos Project Monitor and Asbestos Project Sampling Technician certification shall not perform the functions of both Monitor and Technician during this project.
Air Sampling Technicians Air monitoring technicians must posses valid NYS Asbestos Project Sampling Technician (APST) certificates. Technicians must have performed air sampling for at least 6 months. At a minimum at least 5 Air Sampling Technicians must be assigned to this project. A single individual with Asbestos Project Monitor and Asbestos Project Sampling Technician certification shall not perform the functions of both Monitor and Technician during this project.
Wipe Sampling Technicians Wipe sampling technicians must have 1-year experience in wipe sampling for a variety of contaminants and have received state certified training in dust sampling. At a minimum at least 2 Wipe Sampling Technicians must be assigned to this project.
Equipment Sampling equipment must be in sufficient quantity to provide the amount and type of samples required for this project. The following equipment is required: air-sampling pumps with flow rate capacities of 2 to 10 liters per minute, tripods, rotometers, sample cassettes with mixed cellulose ester filters having pore size of O.Spm, micro vacuum, disposable porous cellulosic towellettes moistened with wetting agent, solvent-wetted sampling agent, and all other equipment required to perform the specified monitoring and sampling.
Analytical Laboratory The environmental laboratory must be certified by the New York State Department of Health. Certification for all the analytes specified herein must have been maintained for at least six (6) consecutive proficiency testing rounds. The laboratory must possess a gas chromatograph equipped with a capillary column and high-resolution mass spectrometer for analyzing dioxin and inductively coupled plasma for total metals.
Proof of qualifications must be presented to the NYCDEP prior to commencement of work. The NYCDEP reserves the right to disqualify any individual(s) from work on this project for non-compliance with these specifications or the requirements of applicable rules and regulations.
Specifications
It is anticipated that the work will be completed within three (3) weeks. Post clean up sampling shall begin within 4 hours of successful visual inspection and shall be completed within 2 days.
Sampling and Analytical Procedures for Lead, PAHs, Dioxin, Fibrous Glass, and Silica
1. Sampling for lead, PAHs, dioxin, fibrous glass, and crystalline silica shall be performed by the wipe sampling technician. A completed chain of custody must accompany all samples. A unique sample number shall be assigned to each sample. A complete written description and/or diagram shall
2 of 6
CITY_21MC100_009915372
NYC-WTC_000454691
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000443993
Draft scope of work for asbestos cleaning and air monitoring at 114 Liberty Street.
13 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000433356
Follow-up DEP scope of work for 114 Liberty Street asbestos/cleaning monitoring.
13 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000442883
Scope of work document for interior cleaning and asbestos monitoring at 114 Liberty Street.
13 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000424654
Draft scope of work for interior cleaning and air monitoring by licensed contractor at 114 Liberty Street.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000429276
Draft chain-of-custody for 114 Liberty Street samples and lab analyses.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000362678
DEP scope of work for asbestos abatement and air monitoring at 114 Liberty Street.
13 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000362690
Document detailing scope of asbestos-related air monitoring and site personnel requirements.
13 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000407441
Scope of work and monitoring plan for asbestos cleaning at 114 Liberty Street.
13 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000407433
Scope of work and monitoring plan for asbestos cleaning at 114 Liberty Street.
13 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000416644
Pre-bid meeting and scope for environmental monitoring during interior cleaning.
12 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155443
Request to verify sampling methodologies and detection limits in the 114 Liberty Street monitoring specifications.
13 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000162815
Request for review of monitoring contractor specifications for air sampling, including sampling methodologies, limits of detection, and clearance criteria, with reference to prior…
13 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000443993
Draft scope of work for asbestos cleaning and air monitoring at 114 Liberty Street.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000433356
Follow-up DEP scope of work for 114 Liberty Street asbestos/cleaning monitoring.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000442883
Scope of work document for interior cleaning and asbestos monitoring at 114 Liberty Street.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000429276
Draft chain-of-custody for 114 Liberty Street samples and lab analyses.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000424654
Draft scope of work for interior cleaning and air monitoring by licensed contractor at 114 Liberty Street.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155443
Request to verify sampling methodologies and detection limits in the 114 Liberty Street monitoring specifications.
Similarity score 0.976 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000443993
Draft scope of work for asbestos cleaning and air monitoring at 114 Liberty Street.
Similar indexed content
NYC-WTC_000433356
Follow-up DEP scope of work for 114 Liberty Street asbestos/cleaning monitoring.
Similar indexed content
NYC-WTC_000442883
Scope of work document for interior cleaning and asbestos monitoring at 114 Liberty Street.
Similar indexed content
NYC-WTC_000424654
Draft scope of work for interior cleaning and air monitoring by licensed contractor at 114 Liberty Street.
Similar indexed content
NYC-WTC_000429276
Draft chain-of-custody for 114 Liberty Street samples and lab analyses.
Similar indexed content