SECTION 02082
(installers) be expert in operations they are engaged to perform.
7. City: The term “City” is defined as City of New York Department of Design and
Construction. City of New York Department of Design and Construction has been
authorized to coordinate construction activities at the site relating to the project
described in the Contract Documents.
8. Provide: Except as otherwise defined in greater detail, term "provide" means furnish
and install, complete and ready for intended use, as applicable in each instance.
9. Testing Laboratory: The term "Testing Laboratory" is defined as an entity
engaged by City and Resident Engineer to perfoim specific inspections or tests of
the work, either at Project site or elsewhere; and to report and (if required)
interpret results of those inspections or tests.
C. Definitions Relative to Asbestos Abatement:
1. Abatement: Procedures physically taken to control fiber release from ACM. This
includes removal, encapsulation, enclosure, and repair.
2. Aggressive Sampling: Method of sampling in which the individual collecting the
air sample creates activity by the use of mechanical equipment during the
sampling period to stir up settled dust and simulate activity in that area of the
building.
3. AIHA: American Industrial Hygiene Association.
4. Airlock: system for permitting entrance and exit while restricting air movement
between a contaminated area and an uncontaminated area. It consists of two
curtained doorways separated by a distance of at least three feet such that one
passes through one doorway into the airlock, allowing the doorway sheeting to
overlap and close off the opening before proceeding through the second doorway,
thereby preventing flow-through contamination.
5. Air Sampling: Process of measuring the fiber content of a known volume of air
collected during a specific period. The procedure utilized for asbestos follows the
NIOSH Standard Analytical Method 7400, or the provisional transmission
electron microscopy methods developed by the US EPA which are utilized for
lower detection levels and specific fiber identification.
6. Amended Water: Water to which a surfactant has been added.
7. ANSI: American National Standards Institute
8. Area Air Sampling: Any form of air sampling or monitoring where the sampling
device is placed at some stationary location.