NYC 9/11 Public Portal Document
Asbestos Air Sampling Results for Staten Island Landfill
Sampling Date and Time: 10/10/01 19:00 to 10/11/01 07:00
PCM by NIOSH 7400 TEM (AHERA)
Sampling Sampling Sample l/mm^ f/cc Structures (#) S/mm^ S~f/cc*
Date Sample No. Location Volume Matrix 0.5-5P >5p
10/11/01 03074 P Loc # 1 718 Air <7.00 <0.004 0 2*. 17.78 0.0095
10/11/01 03075 P Loc # 2 600 Air <7.00 <0.004 0 0 <8.00 <0.0051
10/11/01 03076 P Loc # 3 720 Air 7.64 0.004 0 0 <80.00 <0.0428
10/11/01 03077 P Loc # 4 720 Air <7.00 <0.004 0 0 <8.89 <0.0048
10/11/01 03078 P Loc # 5 720 Air <7.00 <0.004 0 0 <10.00 <0.0053
10/11/01 03079 P Loc # 6 720 Air <7.00 <0.004 0 0 <8.89 <0.0048
10/11/01 03080 P Loc # 7 716 Air <7.00 <0.004 0 0 <10.00 <0.0054
10/11/01 03081 P Loc # 8 720 Air <7.00 <0.004 0 0 <8.89 <0.0048
10/11/01 03082 S Loc # 9A 265 Air <7.00 <0.010 0 0 <8.89 <0.0129
10/11/01 03083 S Loc # 9B 631 Air <7.00 <0.004 0 0 <8.89 <0.0054
10/11/01 03084 S Loc # 9C 507 Air 7.64 0.006 0 0 <8.89 <0.0067
10/11/01 03085 S Loc #10 A 648.3 Air <7.00 <0.004 0 0 <8.89 <0.0053
10/11/01 03086 S Loc# WB 635 Air <7.00 <0.004 0 0 <8.89 <0.0054
10/11/01 03087 W Loc #11 659.2 Air 11.46 0.007 0 3“ 24 0.0140
10/11/01 03088 W Loc #12 657 Air 14.01 0.008 0 8“ 64 0.0376
10/11/01 03089 B Loc# 13 692.2 Air <7.00 <0.004 0 8 0.0044
10/11/01 03090 B Loc # 14 686.3 Air <7.00 <0.004 0 0 <8.00 <0.0045
coc# 04623 ** Chrysotile; no other types of asbestos were detected.
NS: Not sampled
AF/ANF: Asbestos fibers/Non asbestos fibers
Sample volume is below recommended limit of the method:
‘Structure (S) roughly equivalent to fiber (f)
NA: not analyzed due to overloading of particulates
NIOSH 7400: Fiber Analysis of Air samples via NIOSH 7400, Revision 3, Issue 2, 8/15/94
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) EPA 40CFR Part 763 (AHERA)
Standard criteria: EPA 40CFR Part 763 (AHERA): 0.01 fiber/cc (PCM), 70 S/mm', volume 1200 L, for 25 mm filter (TEM)
ERT: 10/14/01 9:50 AM