NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 115 pages

LIMS system chain-of-custody, NYC

Machine-extracted title · confidence 37%

Chain-of-custody/LIMS documentation for NYC Office of the Medical Examiner system.

NYC-WTC_000453885–000453999
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Office of the Chief Medical Examiner Version 2.1 Laboratory Information Management System RFP 27 October 2003

comment on any unusual circumstances or other pertinent information.

Upon completion of the instrument run or the manual batch entry, the analyst will review the screens. The decision to accept or reject the entire run or a portion of the run is made based on this review. The delivered LIMS shall allow for the analyst to make this decision without impacting or otherwise disrupting the normal functioning of the LIMS.

5.20.11.2 LEyEL2

An analyst who was not directly involved in the analysis but is qualified to perform the analysis performs peer review. This analyst looks over the data and checks the calculations. If no mistakes are found, the reviewer selects the approval option on the screen. If errors are found, the delivered LIMS shall allow each reviewer to correct the data, send the data back to the previous level of review, or reschedule for either a re-prep or re-analysis. The reviewer shall also have the ability to approve partial data at this point and send it further along in the process with the delivered LIMS. The LIMS shall have the optional ability to add corrective comments.

5.20.11.3 LEVELS

Supervisory staff shall have access to all quality control data such as calibration information, spike recoveries, blank results. Method Detection Limits (MDLs), Reporting Limits, surrogate values, dilutions, and comments on unusual circumstances or deviations from the SOPs that may have occurred.

The delivered LIMS shall provide Supervisors with the ability to simultaneously validate lower levels of review while approving their own level.

5.20.12 Quality Control Indicators The delivered LIMS shall automatically calculate QC results in terms of percent recovery for calibration check standards and fortified (spiked) specimens and the relative percent difference for duplicates. The latter may be applicable to specimen duplicates. Laboratory Control Specimens (LCS), or matrix spikes. To facilitate the review process, the delivered LIMS shall allow viewing of control charting data in order to readily access the established upper and lower control limits and the delivered LIMS shall permit use of color to differentiate acceptance, warning, and rejection ranges. The delivered System shall permit the reviewer to select the final specimen results to be reported, as well as indicate specimens that must be re-run as a result of the QC review process.

5.20.12.1 QC Resu/t Ca/cu/ab'on

The delivered LIMS shall calculate spike levels for varying specimen size.

©1997-2003 Laboratory Automation Solutions, Inc. 56.

CITY_21MC100_012571840

NYC-WTC_000453940

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000453940Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →