Office of the Chief Medical Examiner Version 2.1 Laboratory Information Management System RFP 27 October 2003

The LIMS shall provide functionality that alerts the user of duplication of barcode numbers when scanning into a sequence or list. For example, when an analyst creates a batch by scanning samples into ordered wells in plates, the LIMS shall provide an audible alert if a duplication of a barcode number occurs in the same plate (or list).

As a second adaptation of this functionality, the LIMS shall provide the means for confirmation of created lists or batches by comparing, audibly or on-screen, scanned barcode to screen displayed barcode, for each sample or QC item in the list or batch. Only after the list or batch is fully confirmed shall the LIMS allow continuance of the process.

5.9 Bar Code Label Printing The delivered LIMS shall be capable of printing bar code labels to dedicated printers based upon the login location of the user. Typically the designated printer will be the closest to the physical location of the user. The OCME LIMS manager will maintain the cross-reference table of bar code printer locations and user locations.

5.10 Soundex Lookup The delivered LIMS application and database shall support Soundex lookups for victims, suspects, decedent's names, addresses, etc. The Soundex searching capability shall be coded using the Basic Soundex Coding Rules and Guide of the National Archives and Records Administration's Soundex Indexing System. The guide can be found at the universal resource locator (URL) http://www.nara.ciov/qenealoqv/soundex/soundex.html

5.11 Instrument & Equipment Maintenance and Calibration Tracking Information relating to each analytical instrument and major OCME asset such as identification code, description, class, serial number, model number, manufacturer, supplier, location, date of purchase, etc. shall be tracked along with calibration and/or maintenance information.

Laboratory instrument and equipment monitoring is critical for maintaining data quality and is part of laboratory certification requirements. The delivered LIMS shall enable monitoring on a fixed schedule or by tracking specified acceptance criterion. This function shall be accomplished directly by the LIMS, as delivered, or by using an external program. Examples of instrumentation and equipment requiring monitoring are:

1. Balances, pH meters, Gas Chromatographs

©1997-2003 Laboratory Automation Solutions, Inc. 38.

CITY_21MC100_0 12571822

NYC-WTC_000453922

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000453922Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →