AMBIENT AIR AND DUST SAMPLING PROTOCOL for PS/IS89M. Page 8 of 8
In the event that any one sample result is unsatisfactory BOE will immediately notify the UFT,
the school principal, the school custodian and the PA consultant. The said parties will assess
the situation and implement the appropriate response action(s).
TVOCs AIR SAMPLES
• First floor hallway, outside cafeteria - one sample.
• Inside playground, north side - one sample.
• Inside playground south side - one sample.
• Fifth floor roof - one sample.
All sample collected shall be analyzed utilizing Hydrocarbon Scan (16+A&B) OSHA 7
method.
Results from samples collected shall be reported to BOE, UFT, School Principal and the PA
consultant in 4 days from the day of sampling.
In the event that any one sample result is unsatisfactory BOE will immediately notify the UFT,
the school principal, the school custodian and the PA consultant. The said parties will assess
the situation and implement the appropriate response action(s).
NOTE: Please note that this protocol established to address the environmental
concerns due to the WTC tragedy. Therefore, this document will be constantly
reviewed and modified as the environmental conditions in Lower Manhattan are
changing.