NYC-WTC_000448447
Duplicate memo describing ultrasonication method for carpet dust; safety benchmarks.
32 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗EPA memo describing ultrasonication method for asbestos in carpets.
NYC-WTC_000453034–000453072OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
APPENDIX B ; ASBESTOS AIR CONCENTRATIONS AND RISKS
Table B gives the cancer risks for exposures to asbestos at different air concentrations. There are 3 different calculations that you must do before using this chart.
1. Estimate the air exposure
From Appendix A, you can estimate the air exposure using the settled dust level. As an alternative, you can use an actual measured air level. Note that the AHERA TEM clearance test level of 70 structures per square millimeter is the same as 0.01 PCM-equivalent f/mL, and is given directly on Table B.
2. Convert the air levels to “PCM-equivalent fibers per milliliter”
The “PCM equivalent” fraction of asbestos fibers are those asbestos fibers at least 5 micrometers (qm) long, with a width greater than 0.25 qm, and an aspect ratio greater than or equal to 3 to 1. These are fibers small enough to be inhaled deeply into the lungs (“respirable size”), but also large enough to be retained by the lungs. It is believed that fibers shorter than 5 gm can be engulfed by macrophages and carried out of the lungs, and do not contribute to cancer.
The older studies upon which the EPA risk assessment levels are based used analytical methods which could only detect the larger, PCM-equivalent fibers. Presumably, the smaller asbestos fibers were also present in the populations addressed by these early studies as well. Thus, it would be incorrect to directly compare newer studies where all sizes of fibers are detected with older studies where only the larger fibers were detected. The way to make the studies comparable is to convert the newer studies data to PCM-equivalents, the units used in the older studies. When the PCM-fraction is unknown for transmission electron microscopy (TEM) levels, a good rule of thumb is to divide by at least 2, if not 4 or more.
3. Convert the 70-vear exposure risk level to shorter exposures
If an exposure is for a shorter period of time than 70 years, multiply the risk level by the fraction of 70 years exposure. For example, if a person is only exposed for 35 years, 24 hours per day, multiply the risk by 14 (multiply by 0.5). If the person is only exposed for 1 year, multiply by 1/70 (multiply by 0.014).
-26-
CITY_21MC100_003234816
NYC-WTC_000453059
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000448447
Duplicate memo describing ultrasonication method for carpet dust; safety benchmarks.
32 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000442045
EPA memo describing ultrasonication carpet testing for asbestos reservoirs.
32 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000433176
EPA memorandum describing ultrasonication test method for asbestos in carpets.
32 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000452613
EPA memorandum describing ultrasonication carpet/asbestos testing method.
32 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000430642
EPA memo on ultrasonication carpet testing for asbestos reservoirs and findings.
32 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000448293
Memorandum describing EPA ultrasonication method for carpet asbestos testing.
32 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000418123
EPA memo describing ultrasonication method for asbestos in carpets and fabrics.
32 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000433551
EPA memo detailing ultrasonication carpet testing method and cost implications.
32 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000451143
EPA memo describing ultrasonication method for carpet/asbestos testing.
32 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000433480
EPA memo on carpet testing method for asbestos and related benchmarks.
32 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000302679
EPA memo detailing ultrasonication carpet test for asbestos in carpets; cost considerations.
31 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000436441
EPA memorandum describing ultrasonication carpet testing for asbestos; guidance and benchmarks.
32 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000448447
Duplicate memo describing ultrasonication method for carpet dust; safety benchmarks.
Similar indexed content
NYC-WTC_000442045
EPA memo describing ultrasonication carpet testing for asbestos reservoirs.
Similar indexed content
NYC-WTC_000433176
EPA memorandum describing ultrasonication test method for asbestos in carpets.
Similar indexed content
NYC-WTC_000452613
EPA memorandum describing ultrasonication carpet/asbestos testing method.
Similar indexed content
NYC-WTC_000430642
EPA memo on ultrasonication carpet testing for asbestos reservoirs and findings.
Similar indexed content