Correspondence on 114 Liberty Street cleanup, 2003

Machine-extracted title · confidence 42%

EPA/DEP review and coordination of WTC dust cleanup data and scope of work for 114 Liberty Street.

NYC-WTC_000452871–000452874
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Risk from asbestos is directly related to its concentration in air. Consequently, post-cleaning aggressive (i.e., use of a leaf blower and fans) air sampling was conducted at 114 Liberty St. by DEP’s contractors to insure that asbestos levels in air met risk-based clearance criteria.

The EMSL analytical report does not provide detailed information on sample collection, however, it appears many samples were collected from inaccessible areas below the hardwood flooring, or from areas of unknown accessibility such as wall tracking, pipe shafts and I-beams. As a matter of precaution, any residual dust and, thus, potential reservoirs of asbestos, from accessible areas should be cleaned using the technique of vacuuming and wet-wiping.

Additionally, asbestos containing materials (ACMs), such as floor tiles, were observed during DEP’s cleaning of the building. Some of the ACMs may be present under the hardwood flooring, thus samples collected from this location may be more representative of the building materials contained within the building rather than indicating contamination from other sources.

It should also be noted that several errors were detected in the calculation of sample concentrations. Two samples had incorrect concentrations reported, samples 221160-02 and 221160-03 (reported on page 6 of the report) should have reported concentrations of 1,471,401 and 432,765 s/cm^ respectively.

Mold and Bacteria Data

Based upon the results that were received, it appears that one sample was collected for mold and bacteria from a kitchen floor and counter on the third floor. The sample was analyzed by P&K Microbiology Services, Inc. with the number and type of fungi and bacteria being counted and identified. Seven fungi species were identified with the highest count for any one species being 900 colony forming units/square inch (Cf l Vin ) and a total sum of 2,200 CFU/in^, while six bacteria species were identified with the highest count for any one species being 500 CblVin’ and a total sum of 1,600 CFU/in^.

Mold

Interpretation of these results cannot be completed using standard practices. The standard practice for determining if an indoor environment is being impacted by mold is to compare the species and concentration of indoor mold samples to outdoor mold samples that were collected during the same sampling event, however, based on the data received it appears that there were no outdoor samples collected for comparison. Using an approach that is less desired than the standard practice, the following conclusions can be drawn from the data. Although there are no specific standards, the general rule of thumb for interpreting mold data usually considers concentrations greater than 10,000 CFU/in^ to be the low end of the spectrum for beginning additional mold investigation, and concentrations greater than 100,000 to signify "mold contamination". The concentrations for each individual species, as well as the total sum for all species was well below 10,000 CFU/in‘. In addition, the fungi species observed are the most

CITY_21MC100_013396011

NYC-WTC_000452873

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000452873Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →