NYC 9/11 Public Portal Document
Report lead as both ug/m^ and ug/fl^
6) Due to the sensitive nature of this project, all data is to be reported on time. Should data be
received beyond the due date the laboratory shall assume the appropriate late charges as agreed
between the Contracting Officer and Region 2.
7) Data turnaround times shall be as follows.
Analyte Analysis Fields Collection Method Data
Code Background and Residential Turnaround
Asbestos* NIOSH 7400 PCM > 5 um_________ Mico vacuum-ASTM D 24 hours
PCMe by TEM asbestos only > 5 um 5755-95, wipe-ATSM D
TEM by AHERA > 0.5 um 6480-99, air-NlOSH 7400, Standard (3 days)
and bulk
Dioxins RPA Method SW-846 8290 Wipe ASTM D 6661-01 14 days
and bulk
Total Dust EPA Method SW-846 8290 Wipe HUD Appendix 13.1 14 days
PAH EPA Method SW-846 8270C Wipe ASTM D 6661-01, 14 days
bulk
Metals EPA Method SW-846 6010B Micro-Vacuum ASTM E 14 days
1973-99, Wipe HUD
Appendix 13.1, Ah NIOSH
7300, and bulk
Mercury EPA Metliod SW-846 7471A Wipe HUD Appendix 13.1, 14 days
Silica, Calcite, NIOSH 7500 (XRD) Wipe HUD Appendix 13.1, 21 days
Gypsum Air NIOSH 7500, and bulk
MMVF EMSL MSD.0300 Collected with asbestos, 14 days
Micro-Vacuum ASTM D
5755-95, Wipe ATSM D
6480-99, NIOSH 7400
MMVF PEMNYS 198.1/EMSL MSD.0300 Collected with asbestos, 14 days
Bulk
*PCM NIOSH 7400, TEM by AHERA method reporting both TEM and PCMe. Samples are collected using a 0.8
um filter pore size.
8) All laboratories analyzing asbestos samples shall be available seven (7) days a week to
receive and analyze samples requested within 24 hours. Results of these analyses must be
submitted electronically to Region 2 and QATS within the 24 requirement.
CITY_21MC100_0 03219233
NYC-WTC_000452809
OCR can misread numbers and units. Confirm readings against the page image before using them.