Ambient air monitoring, 130 Liberty Street, Aug 2005

Machine-extracted title · confidence 50%

Ambient air monitoring program document for the 130 Liberty Street deconstruction project.

NYC-WTC_000452549–000452581
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

6.0 SAMPLING FREQUENCY 6.1 Background

The background ambient air sampling period will consist of two weeks (14 consecutive calendar days) of monitoring performed immediately prior to the start of Phase I - Preparation Phase activities. Samples will be collected at the four (4) ground level stations in the monitoring network (Locations 1-4 in Table 1) and one (1) station located on the roof of the Fire Station situated at 124 Liberty Street (FDNY 10-10 House). All target parameters will be collected over a 24-hour integrated period with the exception of asbestos, silica, PMm, PM25, and mercury utilizing the Lumex instrument. PMwand PM2.5 will be monitored continuously at each of the five (5) sites while asbestos and silica measurements will be taken at a frequency of once per day for eight (8) hours at each of the sites.

6.2 Phase I - Preparation Phase

The Phase I - Preparation Phase air monitoring will follow the schedule and frequency as described below and will commence with the start of Preparations Phase site work.

During the first three (3) days only of Phase I Preparation Phase work, samples will be collected for semivolatile organics to include PCDDs/PCDFs, PAHs and PCBs. After this first three (3) day period, sampling for semivolatile organics will be reduced to a once per week frequency employing the entire station network. One day per week on a rotating basis (week #1 Monday, week #2 Tuesday, etc.) samples will be collected at every station in the network. The schedule will be repeated until project completion.

The semivolatile organic samples collected employing this sampling frequency will not be processed for analyses; rather they will be placed in archival storage at the laboratory. A single set of samples will be selected from each weekly sampling event to undergo analyses for PCDDs/PCDFs, PAHs and PCBs. The station with the highest 24-hour average PMw concentration (ug/m3) recorded with a collocated organic sample each week will be selected for semivolatile organic analyses.

Roof Cleaning: four (4) ground level stations and one (1) off-site elevated station (Locations 1-5 in Table 1) and four (4) rooftop locations. Target parameters for these stations will follow those presented in Section 4.

Scaffold Erection and associated tasks: Scaffold erection up to and including completion of scaffold work on the 10* Floor - four (4) ground level stations and one (1) off-site elevated station (Locations 1-5 in Table 1). Target parameters and the frequency of sample collection for these stations will follow those presented in Section 4. Once the scaffold erection work is completed on the 10* floor, seven (7) additional stations (Locations 6-12) will be installed. Target parameters for these additional stations will follow measures presented in Section 4. As scaffolding is erected, the “floating” stations (Locations 9-12) will move up the building in ten floor increments. See Table 3 for Phase 1 - Minimum Air Sample Phase-In Schedule.

L2005-149(081205)v2 1 5023623.2

CITY_21MC100_002651806

NYC-WTC_000452567

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000452567Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000427190

Chain-of-custody for August 2005 ambient air monitoring at 130 Liberty Street deconstruction site, LMDC.

Similar indexed content

Compare copies and versions →