NYC-WTC_000442364
Foreword and overview of protocol for indoor/dust sampling near World Trade Center.
23 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗Continuation of protocol documentation for WTC dust/air evaluations.
NYC-WTC_000452428–000452473OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
V. Residence Selection/Sampling Rationale The selection of residential sampling locations will be decided upon by New York City Department of Health (NYCDOH). The general NYCDOH approach is described as follows: A total of approximately 60 residential units will be sampled (a unit is an individual apartment in a multi-apartment building). A series of three concentric circles is being drawn around the WTC location. These circles will be divided by direction or zone from the WTC (north, south and west, and east). From five to seven of the multi-residential buildings will be selected for testing from within each zone.
Testing locations will mainly focus on occupied residences. However, approximately five unoccupied units nearest the WTC will be targeted for testing. In addition, approximately five units will be selected outside of the concentric circles, that were not impacted by the WTC collapse, to serve as background sample locations.
Sampling personnel will document the rationale for selecting buildings and residential units for sampling. They will also document sample locations, conditions during sampling, and possible interfering factors (e.g., traffic, construction). In addition, unit occupants and building owner/operators will be requested to provide information that will better assist in evaluating the results. Appendix A of this plan contains the information needed/requested.
VI. Sampling/Analysis Approach 1.Indoor
Air and surface dust sampling will focus on both a common entryway area into the building (e.g., lobbies, front entryways) and on a selected number of apartments/units in the building. Attempts will be made to select apartments/units where dust is visible as well as units where dust is not visible. Selecting entryways and common areas should be representative of worst case conditions for contaminant/material track-in from outdoors. Selecting two apartments/units in the same building-with and without visible dust—should provide information on the ranges of contaminants found in indoor living spaces. If the building is unoccupied and no central HVAC system is present, aggressive (leaf blower, high-power fan) indoor air sampling should be conducted. If the building is occupied, air sampling should be conducted with the building/unit heating, ventilation, and air conditioning (HVAC) system’s fan in continuous operation. After sampling is completed, filters for the HVAC system, if applicable, should be inspected. If dust is present, recommend filter replacement.
Indoor air sampling for asbestos will be conducted and analyzed using NIOSH methods 7400 and 7402. Respirable crystalline silica will be sampled and analyzed using NIOSH method 7500. Air sampling for inhalable and thoracic size particles will be conducted using EPA method IP- 1OA. The respirable silica sample will be used to analyze the respirable fraction of the dust. The relative amounts (percent weight) of each fraction present will be determined . Each fraction will be analyzed for silica, gypsum, mica, and calcite using X-ray diffraction (XRD) analysis. Fibrous glass will be analyzed using scanning electron microscopy (SEM).
5
CITY_21MC100_011228777
NYC-WTC_000452434
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000442364
Foreword and overview of protocol for indoor/dust sampling near World Trade Center.
23 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000452289
Ambient and indoor dust sampling protocol for Lower Manhattan residential buildings.
23 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000449245
Ambient and residential building sampling protocol for WTC-related investigations.
23 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000452382
Continuation of protocol for indoor/dust sampling in Lower Manhattan WTC area.
23 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000443696
Dust and indoor sampling protocol for Lower Manhattan residential buildings after WTC disaster.
23 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000452335
Protocol description for indoor and dust sampling around World Trade Center area.
22 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434617
Chain-of-custody for ambient and indoor dust sampling protocol used in WTC-related residential evaluations, Feb 2002.
23 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000450478
Foreword describing residential building sampling plan and interagency collaboration after 9/11.
23 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000445166
Sampling protocol and foreword for post-9/11 residential indoor and dust assessments in Lower Manhattan.
23 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000445447
Chain-of-custody covering indoor and dust sampling plan after WTC disaster (Feb 2002 Foreword).
23 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000436546
Protocol for indoor/dust sampling around WTC for residential buildings, Feb 2002.
22 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000321656
Duplicated foreword for the WTC residential sampling protocol and group collaboration.
22 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000442364
Foreword and overview of protocol for indoor/dust sampling near World Trade Center.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000445166
Sampling protocol and foreword for post-9/11 residential indoor and dust assessments in Lower Manhattan.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000436546
Protocol for indoor/dust sampling around WTC for residential buildings, Feb 2002.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000433409
Ambient and related sampling plan for post-9/11 WTC-area residences.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000445447
Chain-of-custody covering indoor and dust sampling plan after WTC disaster (Feb 2002 Foreword).
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000435156
Ambient and indoor sampling protocol for WTC-related residential buildings, foreword Feb 2002.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000442364
Foreword and overview of protocol for indoor/dust sampling near World Trade Center.
Similar indexed content
NYC-WTC_000452289
Ambient and indoor dust sampling protocol for Lower Manhattan residential buildings.
Similar indexed content
NYC-WTC_000449245
Ambient and residential building sampling protocol for WTC-related investigations.
Similar indexed content
NYC-WTC_000452382
Continuation of protocol for indoor/dust sampling in Lower Manhattan WTC area.
Similar indexed content
NYC-WTC_000436546
Protocol for indoor/dust sampling around WTC for residential buildings, Feb 2002.
Similar indexed content