NYC-WTC_000445985
Chain-of-custody excerpt referencing Part 763 sections and regulatory definitions.
50 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗Chain-of-custody and SOP excerpt focusing on asbestos validation and PCB spiking.
NYC-WTC_000451982–000452081OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Pt. 763. Subpt. E. App. A 40 CFR Ch. I (7-1-00 Edition) 10. Calibrate sampling pumps and their 17. A minimum of 13 samples are to be col flow indicators over the range of their in lected for each testing site consisting of the tended use with a recognized standard. As following: semble the sampling system with a rep a. A minimum of five samples per abate resentative filter (not the filter which will ment area. be used in sampling) before and after the b. A minimum of five samples per ambient sampling operation. area positioned at locations representative of the air entering the abaleiiient site. 11. Record all calibration information. c. Two field blanks are to be taken by re 12. Ensure that the mechanical vibrations moving the cap for not more than 30 seconds from the pump will be minimized to prevent and replacing it at the time of sampling be transferral of vibration to the cassette. fore sampling is initiated at the following 13. Ensure that a continuous smooth flow places: of negative pressure is delivered by the pump i. Near the entrance to each abatement by damping out any pump action fluctua area. tions if necessary. ii. At one of the ambient sites. (DO NOT 14. The final plastic barrier around the leave the field blanks open during the sam abatement area remains in place for the pling period.) sampling period. d. A sealed blank is to be carried with each 15. After the area has passed a thorough sample set. This representative cassette is visual inspection, use aggressive sampling not to be opened in the field. conditions to dislodge any remaining dust. 18. Perform a leak check of the sampling (See suggested protocol in Unit lII.B.7.d.) system at each indoor and outdoor sampling site by activating the pump with the closed 16. Select an appropriate flow rate equal to sampling cassette in line. Any flow indicates or greater than 1 liter per minute (L/min) or a leak which must be eliminated before initi less than 10 L/min for 25 mm cassettes. Larg ating the sampling operation. er filters may be operated at proportionally 19. The following Table I specifies volume higher flow rates. ranges to be used:
672
CITY_21MC100_003220803
NYC-WTC_000452005
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000445985
Chain-of-custody excerpt referencing Part 763 sections and regulatory definitions.
50 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000442707
Pallet of Part 763 asbestos-related standard references and definitions.
50 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000452898
Chain-of-custody excerpt referencing Part 763 asbestos procedures and compliance.
50 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000449399
EPA Part 763 asbestos SOP excerpt with subparts and scope.
50 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000443893
Chain-of-custody appendix with Part 763 asbestos standards and definitions.
50 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000445234
EPA Part 763 subpart I excerpt regarding asbestos, testing parameters and definitions.
50 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000433711
Page from Part 763 asbestos standard; references to testing and enforcement sections.
50 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434667
Environmental protection document detailing Part 763 asbestos definitions and related sections.
50 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434918
Continuation of the asbestos validation SOP text with definitions and scope.
50 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000435395
Part 763 Subpart text related to asbestos standards and testing definitions.
50 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000438164
EPA SOP excerpts and references for asbestos validation and inspections.
50 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139257
DEP official requests final review of the latest air monitoring Scope of Work to conclude negotiations.
28 shared non-person entities · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000442707
Pallet of Part 763 asbestos-related standard references and definitions.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000445985
Chain-of-custody excerpt referencing Part 763 sections and regulatory definitions.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000443893
Chain-of-custody appendix with Part 763 asbestos standards and definitions.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434918
Continuation of the asbestos validation SOP text with definitions and scope.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000438164
EPA SOP excerpts and references for asbestos validation and inspections.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000435395
Part 763 Subpart text related to asbestos standards and testing definitions.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000445985
Chain-of-custody excerpt referencing Part 763 sections and regulatory definitions.
Similar indexed content
Pallet of Part 763 asbestos-related standard references and definitions.
Similar indexed content
NYC-WTC_000452898
Chain-of-custody excerpt referencing Part 763 asbestos procedures and compliance.
Similar indexed content
NYC-WTC_000449399
EPA Part 763 asbestos SOP excerpt with subparts and scope.
Similar indexed content
NYC-WTC_000443893
Chain-of-custody appendix with Part 763 asbestos standards and definitions.
Similar indexed content