NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 129 pages

Plan for Environmental Community Air Monitoring

Machine-extracted title · confidence 50%

Plan for Greenwich Street and Thames Street air monitoring project, Nov 9, 2005.

NYC-WTC_000451808–000451936
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Part V - Quality Assurance Project Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701 - November 9, 2005

14.5.2.2 PAH and PCB Transformalion and Reduclion

The laboratory will be responsible for calculating the benzo(a)pyrene-equivalent (BAPequivalent) concentration for each sample. The BAP-equivalent concentration will be calculated using potency equivalency factors (PEFs) from the Office of Environmental Hazard Assessment (OEHHA). Each carcinogenic PAH is multiplied by the associated PEE. The resulting values from each carcinogenic PAH are summed to generate the BAP-equivalent concentration. In order to remain conservative, the quantitation limit for nondctcct results will be used in the BAPequivalent concentration calculation. The PEFs which will be used are as follows:

Carcinogenic PAH PEF Benzo(a) anthracene_________ 0.1 Chrysene__________________ 0.01 Benzo(b)_fluroranthene_______ 0.1 Benzo(k) fiuroranthene_______ 0.1 Benzo(a) pyrene____________ 1.0 Indcno( 1,2,3 -cdjpyrcnc 0.1 Dibenz(a,h)anthracene 1.1

14.5.2.3 PCB Reduction

The laboratory will be responsible for calculating the total PCB concentration based on the Aroclor results. If all Aroclors are reported as nondetects, the total PCB results will be equivalent to the sum of the quantitation limits of each individual Aroclor. If one or more Aroclors arc detected, the total PCB concentration will be calculated by summing the detected Aroclors only. If the PCB congener analysis is used due to exceedances ofUSEPA Site-Specific Trigger Eevels as discussed in Section 11.1.2.5, the total PCB concentration will be calculated from the sum of all congeners detected in the analysis.

14.5.3 Data Transfer and Transmittal

Hard copy and EDDs from the laboratories will be transmitted to the AIRTEK Project QA Officer upon completion of analysis, who will forward all deliverables to the AIRTEK Project Manager. Copies of these transmittals will be forwarded to the AIRTEK Project Manager for storage in the project files. Each hard-copy report and EDD will be logged in to AIRTEK’s validation fracking log. As the package proceeds through data validation, review, and data management, the status of the package will be recorded in the log. Completion of validation and final disposition of the package

109

CONFIDENTIAL, CITY_21MC100_0 07850019 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000451916

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000451916Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000426348

Plan document outlining community air monitoring for Greenwich and Thames sites.

Similar indexed content

NYC-WTC_000427716

CoC document for Greenwich/Thames Street air monitoring plan dated Nov 9, 2005.

Similar indexed content

NYC-WTC_000444945

Plan and submittals for environmental community air monitoring at 133-135 Greenwich and 21-23 Thames.

Similar indexed content

NYC-WTC_000440780

Plan document for environmental air monitoring at Greenwich Street and Thames Street sites, dated November 4, 2005.

Similar indexed content

Compare copies and versions →