NYC 9/11 Public Portal Document
<date> PASC - Certificate of Analysis Page 4 of
R02090951 R02090951 R02090951 R02090951
Client ID: lOA llA 12A 13A
Lab No.: 060276 02 060277 02 060278 02 060279 02
Sampled: 12-Scp-2002 12-Scp-2002 12-Scp-2002 12-Scp-2002
Component MDL Units
Total Tctrachlorodibcnzofurans pg 970 180 170 <2.0
Total Pentachlorodibenzofurans 450 110 78 <2.7
Total Hexachlorodibenznfurans 250 4.5 4.5 <2.6
Total Heptachlorodibenzofurans 35 11 11 <3.4
Octachlorodibenzofuran 58 12 16
Total Tetrachlorodibenzo-p-dioxins 1700 230 170 6,6
Total Pentachlorodibenzo-p-dioxins 290 130 56 <4.6
Total Hexachlorodibenzo-p-dioxins 260 14 17 <13
Total Heptachlorodibenzo-p-dioxins 190 90 80 5.0
Octaclilorodibenzo-p-dioxin 730 350 320 13
Internal Recoveries %
2,3,7,8-T4CDF-13C12 93 87 92 86
2,3,7,8-T4CDD-13C12 80 80 85 81
1,2,3,7.8-P5CDF-13C12 88 82 84 79
1,2,3,7.8-P5CDD-13C12 95 88 87 85
1,2,3,4.7,8-H6CDF-13C12 95 90 85 86
1,2,3,6.7,8-H6CDD-13C12 93 93 88 87
1,2,3,4.6,7,8-H7CDF-13C12 85 86 80 78
1,2,3,4.6,7,8-H7CDD-13C12 88 91 85 87
OCDD-13C12 79 86 77 77
2,3,7,8-C14-Dibenzofiiran (DB5) pg 140 28 21 <2.0
2,3,7,8-C14-Dibenzo-p-dioxin <10 <3.4 <3.3 <3.2
1,2,3,7,8-C15-Dibenzofuran <12 <2.2 <6.1 <2.6
2,3,4,7,8-C15-Dibenzofuran 31 13 8.0 <2.8
l,2,3,7.8-C15-Dibenzo-p-dioxin <4.6 <3.5 <3.9 <4.6
1,2,3,4,7,8-C16-Dibcnzofuran 50 15 11
1,2,3,6,7,8-C16-Dibenzofuran 19 <7.0 <5.3 <2.1
2,3,4,6,7,8-C16-Dibenzofuran 22 <7.2 7.8 <2.8
1,2,3,7,8,9-C16-Dibcnzofuran <8.0 <3.7 <4.3 <3.0
1,2,3,4,7,8-C16-Dibenzo-p-dioxin <4.0 <6.2 <16
1,2,3,6,7,8-C16-Diben/o-p-dioxin 9.7 4.4 <4.4 <12
1,2,3,7,8,9-C16-Dibenzo-jydioxin 10 <4.8 <13
1,2,3,4,6,7,8-C17-Dibenzofuran <68 <24 <23 <2.9
1,2,3,4,7,8,9-C17-Dibenzofuran 19 <8.5 <5.2 <3.9
1,2,3,4,6,7,8-C17-Dibenzo-p-dioxin 100 47 40 5.0
1,2,3,4.6,7,8,9-C18-Dibenzofuran 58 12 16
l,2,3,4,6,7,8,9-C18-Dibenzo-p-dioxin 730 350 320 13
2,3,7,8-TCDF (DB225) pg 37 <9.8 <6.7 <8.9
Internal Recoveries %
2,3,7,8-TCDF-13C12 87 86 93 94
TEQ based on Nato Factors pg 44.6 13.9 11.1 6.3
Client:Philip Analytical Services Inc Project:Misc.
CITY_21MC100_003232358
NYC-WTC_000450170