NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 132 pages

Quality Assurance Plan, Ambient Air Monitoring

Machine-extracted title · confidence 66%

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 7, 2005.

NYC-WTC_000449908–000450039
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Ambient Air Monitoring Program Section No. 13 Quality Assurance Project Plan Revision No.: 0 1301 I berly Street - NY, NY Date: September 7, 2005 Lower Manhattan Development Coi-poration Page 91 of 124

Table 13-lc. Maintenance, Testing, and Inspection Requirements for the PS- 1 Sampler Used for PCDDs/PCDFs and PAHs Acceptance Equipment Frequency/Method Corrective Action Criteria Motor Replace as needed Consult manufacturer Obtain the correct for correct model of model motor t ubing and fittings Visually inspect on No crimps, cracks, or Replace as necessary sample recovery days obstructions; no crossthreading

PM III and PM 2 5 Isinu a Reference Sam pier

Tables 13-ld summarizes major maintenance activities for the PM,o and PM2.5 samplers. The manufacturer’s documentation should be consulted for a more exhaustive list of maintenance and inspection procedures.

Table 13-ld. Maintenance, Testing, and Inspection Requirement for the Anderson RAAS Sampler Used for FM m and PM2.5 Acceptance Equipment Frequency/Method Corrective Action Criteria Sampler Dismantle and clean at No obvious Clean or replace inlet/receiver tube manufacturer specified particulate deposits or damaged equipment intervals damage before sampling Power cords Check for crimps or No obvious damage Replace as necessary cracks O-Rings At 3 month intervals, No leaks or Replace as necessary inspect all 0-rings in the compression damage sampler evident Tubing and fittings Visually inspect on No crimps, cracks, or Replace as necessary sample recovery days obshuctions; no crossthreading Vacuum pump Replace diaphragm of NA NA vacuum pump annually

• Field QC Flow Check - The field technicians should perform a single point flow check at the normal operating flow rate on a monthly basis. If the results of the field flow check exceed +10% of the flow rate indicated by the sampler, the sampler should be serviced (if necessary) and a new, full multipoint calibration should be performed.

• Leak Check - The filter used in the sampler is contained within a cassette. A daily leak check is necessary to demonstrate that the portion of the sample flow rate that leaks past the filter without passing through the filter is insignificant relative to the design flow rate of the sampler. The leak check should be performed at 55 mm Hg vacuum or better. Record the initial vacuum. After ten (10) minutes record the final vacuum. Consult the manufacturer’s documentation to find the acceptable criteria for the difference between the initial and final

CITY_21MC100_003218137

NYC-WTC_000449999

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000449999Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000447891

QA plan for ambient air monitoring at 130 Liberty Street, Sept 7, 2005.

Similar indexed content

NYC-WTC_000447031

QA plan document for ambient air monitoring program for Liberty Street deconstruction.

Similar indexed content

NYC-WTC_000443239

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, LMDC.

Similar indexed content

NYC-WTC_000444248

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 2005.

Similar indexed content

Compare copies and versions →