Quality Assurance Plan, Ambient Air Monitoring

Machine-extracted title · confidence 66%

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 7, 2005.

NYC-WTC_000449908–000450039
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Lab EDD Specifications for 130 Liberty Street Deconstruction Project

1) Volume Unit is set as

2) If an analyte is not detected, include the quantitation limit in the concentration column with a flag '<' in the flag column and 'U' in the qualifier column. For detected analytes, the concentration is put in the Concentration column and there is no need to report the quantitation limit.

3) The result units are set differently but consistent with the parameters:

Asbetos PCME f/cm^ AHERA S/mm^ Silica iig/iiL PAHs* ng/m^ Metals ng/m^ Total Mercury ng/m’ Dioxins/furans* pg/m" PCBs ug/m^

* In addition, BAP equivalent (ng/m’) and Dioxin TEQ (pg/m^) concentrations must be calculated and reported in the EDD.

4) Each row in the EDD will contain information for a single analytical result from a single ran of an analytical method, and should be in the format specified below.

Column Field Name Description Format Required #/Name 1/A Lab Name The lab abbreviation that identifies the Text Yes lab to provide the electronic results. 2/B Field Sample ID The sample ID provided by TRC on the Text Yes* chain-of-custody form.________________ 3/C Sample Location The sample location that is provided by Text Yes* TRC on the chain-of-custody. 4/D Date Collected The date that the sample was collected in Date Yes* the field.____________________________ (mm/dd/yyyy) 5/E Volume Collected The sample volume that was collected. Text Yes* Stored as text to preserve significant figures. 6/F Volume Unit A unit associated with the volume Text Yes* collected.___________________________ 7/G Lab Sample ID The sample ID used by the lab Text Yes 8/H Date Received The date that the sample was received by Date Yes* the lab._____________________________ (mm/dd/yyyy) 9/1 Date Analyzed The date that the sample was analyzed by Date Yes the lab. (mm/dd/yyyy)

CITY_21MC100_003218176

NYC-WTC_000450038

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000450038Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000447891

QA plan for ambient air monitoring at 130 Liberty Street, Sept 7, 2005.

Similar indexed content

NYC-WTC_000447031

QA plan document for ambient air monitoring program for Liberty Street deconstruction.

Similar indexed content

NYC-WTC_000443239

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, LMDC.

Similar indexed content

NYC-WTC_000444248

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 2005.

Similar indexed content

Compare copies and versions →