NYC-WTC_000445234
EPA Part 763 subpart I excerpt regarding asbestos, testing parameters and definitions.
50 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗EPA Part 763 asbestos SOP excerpt with subparts and scope.
NYC-WTC_000449399–000449498OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Pt. 763. Subpt. E. App. C 40 CFR Ch. I (7-1-00 Edition) may also choose to issue photo-identifica E. Qualifications tion cards in addition to the required accred In addition to requiring training and an ex itation certificates. amination, a State may require candidates Accredited persons must have their initial for accreditation to meet other qualification and current accreditation certificates al the and/or experience standards that the State location where they are conducting work. considers appropriate for some or all dis 2. The following are the requirements for ciplines. States may choose to consider re examination in each discipline: quiring qualifications similar to the exam a. Worker: ples outlined below for inspectors, manage i. 50 multiple-choice questions ment planners and project designers. States ii. Passing score: 70 percent correct may modify these examples as appropriate. b. Contractor/Supervisor: In addition. States may want to include i. 100 multiple-choice questions some requirements based on experience in ii. Passing score: 70 percent correct performing a task directly as a part of a job c. Inspector: or in an apprenticeship role. They may also i. 50 Multiple-choice questions wish to consider additional criteria for the ii. Passing score: 70 percent correct approval of training course instructors be d. Management Planner: yond those prescribed by EPA. i. 50 Multiple-choice questions 1. Inspectors: Qualifications - possess a ii. Passing score: 70 percent correct high school diploma. States may want to re e. Project Designer: quire an Associate’s Degree in specific fields i. 100 multiple-choice questions (e.g., environmental or physical sciences). ii. Passing score: 70 percent correct 2. Management Planners: Qualifications - Registered architect, engineer, or certified D. Continuing Education industrial hygienist or related scientific For all disciplines, a State’s accreditation field. program shall include annual refresher train 3. Project Designers: Qualifications - reg ing as a requirement for reaccreditation as istered architect, engineer, or certified in indicated below: dustrial hygienist. 1. Workers: One full day of refresher train 4. Asbestos Training Course Instructor: ing. Qualifications - academic credentials and/or 2. Contractor/Supervisors: One full day of field experience in asbestos abatement. refresher training. EPA recommends that States prescribe 3. Inspectors: One half-day of refresher minimum qualification standards for train training. ing instructors employed by training pro 4. Management Planners: One half-day of viders. inspector refresher training and one half-day F. Recordkeeping Requirements for Training of refresher training for management plan Providers ners. 5. Project Designers: One full day of re All approved providers of accredited asbes fresher training. tos training courses must comply with the The refresher courses shall be specific to following minimum recordkeeping require each discipline. Refresher courses shall be ments. conducted as separate and distinct courses 1. Training course materials. A training and not combined with any other training provider must retain copies of all instruc during the period of the refresher course. For tional materials used in the delivery of the each discipline, the refresher course shall re classroom training such as student manuals, view and discuss changes in Federal, State, instructor notebooks and handouts. and local regulations, developments in state- 2. Instructor qualifications. A training pro of-the-art procedures, and a review of key as vider must retain copies of all instructors’ pects of the initial training course as deter resumes, and the documents approving each mined by the State. After completing the an instructor issued by either EPA or a State. nual refresher course, persons shall have Instructors must be approved by either EPA their accreditation extended for an addi or a State before teaching courses for accred tional year from the date of the refresher itation purposes. A training provider must course. A State may consider requiring per notify EPA or the State, as appropriate, in sons to pass reaccreditation examinations at advance whenever it changes course instruc specific intervals (for example, every 3 tors. Records must accurately identify the years). instructors that taught each particular EPA recommends that States formally es course for each date that a course is offered. tablish a 12-month grace period to enable 3. Examinations. A training provider must formerly accredited persons with expired document that each person who receives an certificates to complete refresher training accreditation certificate for an initial train and have their accreditation status rein ing course has achieved a passing score on stated without having to re-take the initial the examination. These records must clearly training course. indicate the date upon which the exam was
718
CITY_21MC100_011980845
NYC-WTC_000449468
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000445234
EPA Part 763 subpart I excerpt regarding asbestos, testing parameters and definitions.
50 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000452898
Chain-of-custody excerpt referencing Part 763 asbestos procedures and compliance.
50 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000445985
Chain-of-custody excerpt referencing Part 763 sections and regulatory definitions.
50 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000442707
Pallet of Part 763 asbestos-related standard references and definitions.
50 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000451982
Chain-of-custody and SOP excerpt focusing on asbestos validation and PCB spiking.
50 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000443893
Chain-of-custody appendix with Part 763 asbestos standards and definitions.
50 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000438164
EPA SOP excerpts and references for asbestos validation and inspections.
50 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434918
Continuation of the asbestos validation SOP text with definitions and scope.
50 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000435395
Part 763 Subpart text related to asbestos standards and testing definitions.
50 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000433711
Page from Part 763 asbestos standard; references to testing and enforcement sections.
50 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434667
Environmental protection document detailing Part 763 asbestos definitions and related sections.
50 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139257
DEP official requests final review of the latest air monitoring Scope of Work to conclude negotiations.
28 shared non-person entities · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000433711
Page from Part 763 asbestos standard; references to testing and enforcement sections.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434667
Environmental protection document detailing Part 763 asbestos definitions and related sections.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000435395
Part 763 Subpart text related to asbestos standards and testing definitions.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000445234
EPA Part 763 subpart I excerpt regarding asbestos, testing parameters and definitions.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434918
Continuation of the asbestos validation SOP text with definitions and scope.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000438164
EPA SOP excerpts and references for asbestos validation and inspections.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000445234
EPA Part 763 subpart I excerpt regarding asbestos, testing parameters and definitions.
Similar indexed content
NYC-WTC_000452898
Chain-of-custody excerpt referencing Part 763 asbestos procedures and compliance.
Similar indexed content
NYC-WTC_000445985
Chain-of-custody excerpt referencing Part 763 sections and regulatory definitions.
Similar indexed content
Pallet of Part 763 asbestos-related standard references and definitions.
Similar indexed content
NYC-WTC_000451982
Chain-of-custody and SOP excerpt focusing on asbestos validation and PCB spiking.
Similar indexed content