NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 100 pages

ASB Part 763 SOP excerpt, EPA 763 rules

Machine-extracted title · confidence 32%

EPA Part 763 asbestos SOP excerpt with subparts and scope.

NYC-WTC_000449399–000449498
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

§ 763.86 40 CFR Ch. I (7-1-00 Edition) that samples are collected, homo­ (vi) Reassess, under § 763.88, the con­ geneous areas where friable suspected dition of friable known or assumed ACBM is assumed to be ACM, and ho­ ACBM previously identified. mogeneous areas where nonfriable sus­ (vii) Record the following and submit pected ACBM is assumed to be ACM. to the person designated under § 763.84 (C) A description of the manner used a copy of such record for inclusion in to determine sampling locations, the the management plan within 30 days of name and signature of each accredited the reinspection: inspector who collected the samples. (A) The date of the reinspection, the State of accreditation, and, if applica­ name and signature of the person mak­ ble, his or her accreditation number. ing the reinspection. State of accredi­ (D) A list of whether the homo­ tation, and if applicable, his or her ac­ geneous areas identified under para­ creditation number, and any changes graph (a)(4)(vi)(B) of this section, are in the condition of known or assumed surfacing material, thermal system in­ ACBM. sulation, or miscellaneous material. (B) The exact locations where sam­ (E) Assessments made of friable ma­ ples are collected during the reinspec­ terial, the name and signature of each tion, a description of the manner used accredited inspector making the as­ to determine sampling locations, the sessment, State of accreditation, and if name and signature of each accredited applicable, his or her accreditation inspector who collected the samples. number. State of accreditation, and, if applica­ (b) Reinspection. (1) At least once ble, his or her accreditation number. every 3 years after a management plan (C) Any assessments or reassess­ is in effect, each local education agen­ ments made of friable material, the cy shall conduct a reinspection of all name and signature of the accredited friable and nonfriable known or as­ inspector making the assessments. sumed ACBM in each school building State of accreditation, and if applica­ that they lease, own, or otherwise use ble, his or her accreditation number. as a school building. (c) Crenerat. thermal system insula­ (2) Each inspection shall be made by tion that has retained its structural in­ an accredited inspector. tegrity and that has an undamaged (3) For each area of a school building, protective jacket or wrap that prevents each person performing a reinspection fiber release shall be treated as nonfri- shall: able and therefore is subject only to (i) Visually reinspect, and reassess, periodic surveillance and preventive under §763.88, the condition of all fri­ measures as necessary. able known or assumed ACBM. (ii) Visually inspect material that §763.86 Sampling. was previously considered nonfriable ACBM and touch the material to deter­ (a) Surfacing material. An accredited mine whether it has become friable inspector shall collect, in a statis­ since the last inspection or reinspec­ tically random manner that is rep­ tion. resentative of the homogeneous area, (iii) Identify any homogeneous areas bulk samples from each homogeneous with material that has become friable area of friable surfacing material that since the last inspection or reinspec­ is not assumed to be ACM, and shall tion. collect the samples as follows: (iv) For each homogeneous area of (1) At least three bulk samples shall newly friable material that is already be collected from each homogeneous assumed to be ACBM, bulk samples area that is 1,000 fC or less, except as may be collected and submitted for provided in § 763.87(c)(2). analysis in accordance with §§763.86 (2) At least five bulk samples shall be and 763.87. collected from each homogeneous area (v) Assess, under §763.88, the condi­ that is greater than 1,000 fC but less tion of the newly friable material in than or equal to 5,000 fC, except as pro­ areas where samples are collected, and vided in § 763.87(c)(2). newly friable materials in areas that (3) At least seven bulk samples shall are assumed to be ACBM. be collected from each homogeneous

6S4

CITY_21MC100_011980781

NYC-WTC_000449404

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000449404Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000442707

Pallet of Part 763 asbestos-related standard references and definitions.

Similar indexed content

Compare copies and versions →