NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 46 pages

WTC ambient evaluations protocol, Feb 2002

Machine-extracted title · confidence 32%

Ambient and residential building sampling protocol for WTC-related investigations.

NYC-WTC_000449245–000449290
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Co-located samples will be collected in 10% of the air samples. While not a true duplicate, evaluation of the results will provide some information on the quality of the sampling technique. Generally, analysis of duplicate samples should be within +/- 25% of each other.

At least two field blanks (or 10% of samples submitted, whichever is greater) per air sample method per sample team will be submitted with the air samples collected each day. Blank cassettes should be opened at the same time as the sample cassettes are opened (just prior to sampling). Blank cassettes will be recapped and stored in a clean area (e.g., closed bag or box) with the covers from the sampling cassettes during the sampling period. Each air sampling pump will be calibrated with a representative sampling device in-line before and after sample collection. Sample flow rates will be documented in the sampling log. The average of pre- and post-calibration flow rates will be used as the sample flow rate, for sample volume calculations.

Dust samples will be collected using the U.S. Environmental Protection Agency (EPA) Environmental Response Team (ERT) indoor dust sampling standard operating procedure (SOP). Duplicate samples are not feasible with indoor surface dust sample collection. Co-located samples (samples collected from adjacent areas of the floor) will be collected in 10% of the indoor surface dust sample locations. While not a true duplicate, evaluation of the results will provide some information on the variability of contaminants in the dust.

Samples should not be packaged in untreated polystyrene-electrostatic forces may cause fiber loss from some sample filters.

Chain of custody will be established and maintained throughout sample collection, transport, and analysis of the samples. Laboratory analysis shall follow all method-required quality assurance and quality control procedures.

All samples collected, unless analyzed with destructive methods, will be archived until further notice.

3

CITY_21MC100_0 03230969

NYC-WTC_000449249

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000449249Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →