NYC 9/11 Public Portal Document

(11) Exhaust Location. The exhaust shall be vented to the outside of the building or structure, to a controllable area away from public access. Each negative pressure ventilation unit exhaust duct shall not terminate less than fifteen (15) feet from a receptor or adversely affect the air intake of any building or structure. If the exhaust duct termination location for this Section cannot be met due to allowable space restrictions or the regulated abatement work area being located above the ground floor, the exhaust shall terminate at the exterior of the building or structure, and all receptors less then fifteen (15) feet from the exterior exhaust duct termination location shall be plasticized with two (2) layers of at least 6 mil polyethylene. Exhaust tubes may be grouped together in banks of no more than five (5) tubes, with each tube exhausting separately and the bank of tubes terminating together at the same controlled area. (i) Exception. HEPA-filtered vacuums used to exhaust Minor size tent enclosure regulated abatement work areas do not require exhausting to the exterior of the building/structure. (12) Booster Exhaust Fan Units. If exhaust ducting in excess of 25 feet in length is attached to any ventilation unit, an unfiltered booster fan of equal flow capacity shall be installed per 25 foot of downstream exhaust ducting from the ventilation unit. Non-collapsible exhaust ducting shall be used between the booster fan units and also between the ventilation units and the booster fan units. Where possible, these booster fan units shall be installed and operated outside of the regulated abatement work area. However, booster fan units installed and operated outside the regulated abatement work area still require installation using GFCI protected temporary power circuits. (b) Exemption From Ventilation And Use of Negative Pressure Equipment. (1) The use of negative pressure air equipment is not required for the following: (i) OSHA Class II non-friable ACM exterior projects; (ii) asbestos projects where enclosures (i.e. hard walls, tents, etc.) are not required by this Part; (iii) demolition asbestos abatement projects. (2) This exemption does not relieve the asbestos abatement contractor from the negative pressure equipment requirements on other portions of the same project that require the use of negative pressure equipment. 56-7.9 Heating, Ventilation, and Air Conditioning (HVAC) Systems (a) Isolation. HVAC systems shall be isolated from the regulated abatement work area. Acceptable means of HVAC system isolation include: (1) Shutdown and Isolation. Shutdown and isolation of HVAC systems to prevent contamination and asbestos dispersal to other areas of the building or structure.

12 NYCRR56 Subparty, Page 64

CITY_21MC100_003234513

NYC-WTC_000448395

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000448395Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Asbestos, NY DOL reference

NYC-WTC_000441450

Asbestos standards reference page from NY Department of Labor materials.

Similar indexed content

Asbestos sampling chain of custody form

NYC-WTC_000233286

Chain of custody form for asbestos samples referencing New York State Department of Labor regulations and sample tracking details.

Similar indexed content

Compare copies and versions →