Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - Rev 1 - January 27, 2006
Ignitability American Society of American Society of
Testing Materials (ASTM) Testing Materials (ASTM)
method D-93-79 or D-93-80 method D-93-79 or D-93-80
or D-3278-78._____________ or D-3278-78.
Corrosivity NA SW-846 Method 9040C
(aqueous) / 9045D (solid)
Reactive Cyanide SW846 Ch. 7.3.3__________ SW846 Ch. 7.3.3
Reactive Sulfide SW846 Ch. 7.3.4__________ SW846 Ch. 7.3.4
PCBs SW-846 Metlrod 3541 or 3545 or SW-846 Metlrod 8082
(for characterization and 3550B
disposal)
T0-9A Determination of Polychlorinated , Polibrominated and Brominated/Chlorinated
Dibenzo-p-Dioxin and Dibenzofurans in Ambient Air, January 1999
TO-lOA Determination of Pesticides and Polychlorinated Biphenyls in Ambient Air Using
Low Volume Polyurethane Foam (PUF) sampling followed by Gas
Chromatographic/Multi Detector Detection (GD/MD), January 1999.
T0-13A: Determination of Polycyclic Aromatic Hydrocarbons (PAHs) in Ambient Air
Using Gas Chromatographic/Mass Spectrometry (GC/MS), January 1999.
11.1.2.3 Asbestos Analyses by TEM (AHERA)
Asbestos analysis will be performed utilizing Transmission Electron Microscopy (TEM)
analysis specified in 40 CFR Part 763, Asbestos Hazard Emergency Response Act,
(AHERA) in order to measure structures/mmz, with the following modifications:
• The sensitivity on TEM air samples will be less than 0.002 structures/cc. The
laboratory will analyze up to 10 grid openings on the TEM in order to achieve
this sensitivity.
• Both length and width of all asbestos fibers will be recorded. • Confirmation by
Energy Dispersive Spectroscopy (EDS) and/or Selected Area Electron Diffraction
(SAED) will be performed for each sample.
The morphology of the fibers will be noted by the aspect ratio and recorded. In addition
to the standard AHERA analysis provided for each sample, a second analysis will
be performed for asbestos PCM equivalent (PCME) fibers. These fibers will be defined
as any asbestos fiber or bundle with the following features:
• an aspect ratio of 3:1 or greater
• greater than 5 microns in length
Analysis will be performed at a magnification of approximately 2000x with
higher magnifications of 10,000 and 20,000x used as needed for precise measurements
and identification of individual fibers. Only PCME fibers (both asbestos and non-
74
CITY_21MC100_011979814
NYC-WTC_000448158