NYC 9/11 Public Portal Document
Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - Rev 1 - January 27, 2006
laboratory. The laboratory completeness objective will be a minimum of 90 percent. This
allows for the potential loss of samples impossible to analyze due to unforeseen
interferences and rejected data following data validation.
9.0 NON-DIRECT MEASUREMENTS (SECONDARY DATA) Previously collected
data and information will not be used to make project decisions or design the sampling
program. However, data from the 130 Liberty Street Project will be used in this project.
All field, laboratory, and validation methods for the two projects have been designed so
as to be comparable and will be collected contemporaneously. National weather service
and 130 Liberty Street meteorological data will be used for this project, utilizing standard
methods, and will provide data sufficiently representative of local conditions as stated in
section 10.1.
10.0 FIELD MONITORING REQUIREMENTS
10.1 Monitoring Process Design
Refer to Section 7.1.1 for the monitoring design of this project. This section discusses the
areas being sampled, what is being tested, and how often.
10.1.1 Meteorological Data Collection
Potential sources of variability may be due to meteorological data. Data available from
regional National Weather Stations (NWS) such as Newark Airport, LaGuardia and
Kennedy Airports can be used to complement the localized data but it is likely NWS data
may not always be representative of conditions in and around the 133-135 Greenwich
Street and 21-23 Thames Street site. A meteorological station that will be deployed by
LMDC as part of the 130 Liberty Street deconstruction project in the immediate vicinity
of the site may be utilized where needed to provide local meteorological data for
comparison with monitoring data results.
10.2 Monitoring Methods
The following sections provide a brief description of the sampling procedures to be
employed for each parameter and a summary of the required equipment. Step-by-step
operating procedures are included as Attachment C.
10.2.1 Metals (MCE Filters)
Samples to be analyzed for metals will be collected employing low-volume air sampling
techniques in accordance with NIOSH 7300. Samples will be collected over
approximately a twenty-four hour sampling period. During this period ambient air will be
collected at a flow rate of approximately 4 liters/minute. Mixed cellulose ester (MCE)
filters provided by the subcontracted laboratory will be placed in each sampling system
58
CITY_21MC100_011979798
NYC-WTC_000448142
OCR can misread numbers and units. Confirm readings against the page image before using them.