written reports; in addition, verbal debriefings will also be held at the conclusion of
all audits. The reports will be prepared by the auditor and will describe the scope of
the TSA, summarize audit findings, and recommend corrective action. The report will
be distributed to the appropriate personnel for response: the AIRTEK Field Sampling
Coordinator will be responsible for responding to the field sampling TSA report, and
the Eaboratory Manager will be responsible for addressing the fixed laboratory TSA
report. Significant issues that are discovered during the TSA and which could
potentially affect data quality or usability will be brought to the immediate
attention of the AIRTEK Project Manager. The response to the TSA reports will
include a description of the corrective action(s) to be implemented, the identities of
the personnel responsible for implementing the corrective action, and the schedule for
implementation/completion. All responses must be completed within two weeks of
issuing the TSA report. The response will be reviewed by the AIRTEK Project QA
Officer and/or AIRTEK Project Manager and, if all issues have been addressed
appropriately and in a timely manner, no further action will be required. In the event
that the corrective action(s) are inadequate or inappropriate, follow-up activities,
including additional audits, or discussions with the AIRTEK Project Manager, will be
conducted by the AIRTEK Project QA Officer. The complete TSA report, including
resolution of any deficiencies, will be included in the QA reports to management.
15.3 Additional QAPP Non-Conformances
15.3.1 Field Non Conformances
Corrective action in the field may be needed when the sample network is changed
(i.e., more/less samples, sampling locations other than those specified in the QAPP),
or when sampling procedures and/or field analytical procedures require modification,
etc. due to unexpected conditions. The field team may identify the need for corrective
action. The AIRTEK Field Sampling Coordinator will approve the corrective action
and notify the AIRTEK Project Manager and AIRTEK QA Officer. The AIRTEK
Project Manager, in consultation with the EPA Region 2 Project Manager,
if necessary, will approve the corrective action. The AIRTEK Field Sampling
Coordinator will ensure that the corrective action is implemented by the field team.
Corrective actions will be implemented and documented in the field logbook.
Documentation will include:
• A description of the circumstances that initiated the corrective action,
• The action taken in response,
• The final resolution, and
• Any necessary approvals.
No staff member will initiate corrective action without prior communication of
findings through the proper channels as described above All corrective actions will
take into account the possible effect on the data. If necessary, a problem resolution
audit will be conducted.