Quality Assurance Plan, Ambient Air Monitoring

Machine-extracted title · confidence 46%

QA plan for ambient air monitoring at 130 Liberty Street, Sept 7, 2005.

NYC-WTC_000447891–000448022
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

Z ■< z ■<

o o io Ambient Air Monitoring Program Quality Assurance Project Plan 130 liberly Street - NY, NY Section No. 7 Revision No.: 0 Date: September 7, 2005 co

I ■D o Lower Manliattan Development Corporation Page 34 of 124 c o CT o o' ■D CD o to 3. cn 03 Table 7-lc. Phase II - Structural Deconstruction o o No. of o No. of No. of c Locations No. of Estimated No. 3 Locations Locations No. of Field CD Sampled Per Field/Trip Estimated No. of Samples to Sampled Sampled Per Duplicates Day Blanks of Samples to Lab Per Week Per Day Day Collected (After 1’* 3 Collected Lab Fer Day (After 1’* 3 (Preparation (P‘ 3 Days of Per Week Days of Per Day Days) Phase) Phase I) Phase I) Metals 12 12 12 1 1 13 92 Mercury - Total 12 12 12 1 1 13 92 Asbestos 12 12 12 1 1 13 92 PM 10 -reference 1 1 1 1 1 1 9 PM2.5 -reference 1 1 1 1 1 1 9 Silica 12 12 12 1 1 13 92 Dioxins/Furans 12 12 1 1 13 3 PCBs 12 12 1 1« 1 13<’> 3 PAHs 12 12 1 1 W 1 13<‘> 3 Thirteen (13) samples per day for first 3 days of Phase 1; followed by 1 location per week based on highest PMio concentrations. Held duplicates may not be consistently collected at a frequency of 1/week during Phases 1 and 11 as the location selected for analysis will be dictated by PMio measurements.

o H K I to s O o o I o o co to

CO o

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000447925Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000449908

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 7, 2005.

Similar indexed content

NYC-WTC_000447031

QA plan document for ambient air monitoring program for Liberty Street deconstruction.

Similar indexed content

NYC-WTC_000443239

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, LMDC.

Similar indexed content

NYC-WTC_000444248

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 2005.

Similar indexed content

Compare copies and versions →