Ambient Air Monitoring Program Section No. 13 Quality Assurance Project Plan Revision No.: 0 1301 I berly Street - NY, NY Date: September 7, 2005 Lower Manhattan Development Coi-poration Page 102 of 124

The use of materials of known purity and quality will be utilized for the calibration of all instruments as part of this project. The laboratories will carefully monitor the use of all laboratory materials including solutions, standards and reagents through well documented procedures.

All solid chemicals and acids/bases used by the laboratories will be reagent grade or better. All gases will be high purity or better. All standards or standard solutions will be obtained from U.S. Environmental Protection Agency certified commercial sources.

All materials including standards or standard solutions will be dated upon receipt, and will be identified by material name, lot number, purity or concentration, supplier, receipt/preparation date, recipient/preparer’s name, and expiration date.

Standards or standard solution concentrations will be validated prior to use. This validation may be re standardization for acids and bases, response factor comparison, standard curve response, comparison to other standards made at a different time and/or by a different analyst. All standards and standard materials will be checked for signs of deterioration including unusual volume changes (solvent loss), discoloration, formation of precipitates or changes in analyte response. All standards and standard solutions will be properly stored and handled and will be labeled with all appropriate information including compound/solution name, concentration, solvent, expiration date, preparation date, and the initials of the preparer.

All solvent materials or materials used as part of a given procedure will also be checked. Each new lot of solvent will be analyzed to ensure the absence of interference.

CITY_21MC100_003219938

NYC-WTC_000447993

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000447993Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000449908

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 7, 2005.

Similar indexed content

NYC-WTC_000447031

QA plan document for ambient air monitoring program for Liberty Street deconstruction.

Similar indexed content

NYC-WTC_000443239

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, LMDC.

Similar indexed content

NYC-WTC_000444248

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 2005.

Similar indexed content

Compare copies and versions →