NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 33 pages

Ambient air monitoring program, Deconstruction, May 2005

Machine-extracted title · confidence 52%

Chain-of-custody and project header for ambient air monitoring at 130 Liberty Street Deconstruction, May 2005.

NYC-WTC_000447726–000447758
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

discretion of the Environmental Consultant and as daily site conditions may dictate, additional mercury readings may be taken.

5.5 Mercury (Vapor/Gas)

A separate sampling and analysis method is required for mercury, as field studies have indicated that atmospheric mercury is generally greater than 95% in the vapor phase. An iodated carbon trap will be analyzed for total elemental mercury (particulate associated/vapor) using cold vapor atomic fluorescence (CVAF). The carbon trap is a proven and sensitive method for detecting trace ambient levels of atmospheric mercury. To collect the mercury sample, a high volume pump will be attached to the carbon trap and set at a flow rate of approximately 4 liter per minute.

5.6 Respirable Dust and Crystalline Silica

Respirable dust and crystalline silica sampling will be performed according to NIOSH Method 0600 protocol with analysis following NIOSH Method 7500 (XRD).

5.7 Semivolatile Organics (PCDDs/PCDFs, PAHs, PCBs)

Each site will have two (2) General Metal Works (GMW) model PS-1 high volume air samplers to collect 24-hour samples of PAH, Dioxin/Euran and PCBs, following USEPA Method TO- 13A, TO 9A, and TO-4A, respectively. One sampler will be used for PAHs. A second sampler will be use for both PCBs and D/Fs. Method TO-13A, TO4A, and TO-9A use the PS-1 samplers to draw air through a sampling train consisting of a 102 millimeters diameter microquartz filter first to collect the semivolatile PAH particulates and then a glass cylinder holding a polyurethane foam (PUF) plug (1 inch of XAD-2 adsorbent resin is used in the middle of the PAH sampling media) to collect the semivolatile vapors. The entire sampling train (filter, XAD-2, and PUF plugs) are extracted together and analyzed for speciated PAH, PCBs, and D/Fs compounds using gas chromatography/mass spectrometry. The samplers will be set to run at approximately 250 liters per minute resulting in a total air volume of 360 m^ over the prescribed 24-hour sampling period.

L2005-149(051205) 4 5023623.2

CITY_21MC100_002652325

NYC-WTC_000447741

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000447741Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →