NYC 9/11 Public Portal Document

Ambient Air Monitoring Program Section No. 10 Quality Assurance Project Plan Revision No.: 0 1301 I berly Street - NY, NY Date: September 7, 2005 Lower Manhattan Development Coi-poration Page 64 of 124

200 to 300 liters per minute (1pm) over a sampling period of approximately 24 hours for a resulting total air volume of approximately 288-432 cubic meters (288-432 m^).

The PUF (Polyurethane Foam) sampler is a complete air sampling system designed to simultaneously collect suspended airborne particulates as well as trap airborne organic vapors. The PUF sampler is equipped with a bypass blower motor arranged with an independent cooling fan. This feature permits the motor to operate at low sampling flow rates for extended periods without motor failure from overheating.

A dual chambered aluminum sampling module contains both filtering systems. The upper chamber supports the airborne particulate filter media in a circular filter holder. The lower chamber encapsulates a glass cartridge, which contains the PUF for vapor entrapment.

The voltage variator adjustment screw alters the blower motor speed to achieve the desired flow rate. Air flow rate is measured through the flow venturi utilizing a 0-100” Magnehelic Gage. For each sample, the sampling start and end times and flow rates are recorded on Field Sampling Data Sheets or an equivalent field logbook and used to calculate the amount of ambient air sampled.

At the conclusion of each sampling period, the sample is recovered from the sampling train by placing the filter inside the glass cartridge. The glass cartridge is then wrapped with aluminum foil and it is placed back into its original shipping container, labeled, and transported to the analytical laboratory for processing.

Equipment and supplies utilized with this sampling approach are as follows:

• High-Volume Sampler - General Metals Works (GMW) PS-1 (or equivalent), capable of pulling ambient air through the filter/adsorbent cartridge sampling train at a flow rate of 200- 300 1pm to obtain a total sample volume of 288-432 m^ over a 24-hour period.

• High-Volume Sampler Calibrator - Capable of providing multipoint resistance for the high- volume sampler.

• Quartz Fiber Filters - 102 millimeter (102-mm) bindless quartz microfiber filter, Whatman International Ltd, QMA-4 (or equivalent), provided by the laboratory, pre-cleaned and weighed.

• Polyurethane Foam (PUF) Plugs - 3-inch thick sheet stock polyurethane type (density 0.022 g/cm3). Plugs should be slightly larger in diameter than the internal diameter of the cartridge.

• Teflon® End Caps - For sample cartridge. Must fit tightly to provide an adequate seal to prevent pre- or post- samphng exposure to other potential sources of the target analytes.

CITY_21MC100_003212810

NYC-WTC_000447095

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000447095Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000449908

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 7, 2005.

Similar indexed content

NYC-WTC_000447891

QA plan for ambient air monitoring at 130 Liberty Street, Sept 7, 2005.

Similar indexed content

NYC-WTC_000443239

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, LMDC.

Similar indexed content

NYC-WTC_000444248

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 2005.

Similar indexed content

Compare copies and versions →