Quality Assurance Plan, Ambient Air Monitoring, LMDC

Machine-extracted title · confidence 39%

QA plan document for ambient air monitoring program for Liberty Street deconstruction.

NYC-WTC_000447031–000447162
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

z ■< Z ■<

o Ambient Air Monitoring Program Section No. 8 o co g Quality Assurance Project Plan Revision No.: 0 o 130 Liberty Street - NY, NY Date: September 7, 2005 I “0 o Lower Manhattan Development Corporation Page 49 of 124 c o CT o o' "0 o o oo 03 o Table 8-5. Measurement Performance Criteria Table - PCDDs/PCDFs by HRGC/HRMS O o QC Sample or Activity Frequency Measurement Performance Criteria Corrective Action DQI o c Field Duplicates l/week^’^ *RPD < 40 when positive results for both Assess laboratory precision, and/or Precision-Overall 3 CD samples are > 5x QL qualify data. 3 *No situation where one result is detected at > 5x QL and other result is not detected Extraction Standards Every sample, Percent recoveries 50-120% for teha-hexa Reanalyze and/or qualify data. Accuracy/Bias (pre-extraction) blank, QC congeners and 40-120% for hepta and octa congeners Field Spikes Every sample, Percent recoveries 70-130% Reanalyze and/or qualify data. Accuracy/Bias (pre- sampling) blank, QC Laboratory Control Sample 1/batch Percent differences between LCS RRF and Determine cause of problem, Accuracy/Bias (BCS3) (10 samples) ICAL RRF < 20 reanalyze, and/or qualify data. 2/analytical RPD between 2 LCS analyses < 20 Determine cause of problem, Precision sequence reanalyze, and/or qualify data. Method Blanks 1/batch No target compounds > QL Reclean, reanalyze and/or qualify Accuracy/Bias- data. Contamination Field/Trip Blanks l/day<’> No target compounds > QL Reclean, reanalyze, and/or qualify Accuracy/Bias - data. Contamination PUF Media Cleaning 1/batch cleaned No target compounds > QL Reclean and retest media. Accuracy/Bias- Verification Check Contamination Recovery Standards Every sample, Signal: noise ratio must be > 10:1 Reanalyze and/or qualify data. Accuracy/Bias blank, QC Data Completeness Check NA Field 80%, Laboratory 95% NA Data Completeness •'’includes the following compounds: 3’'C14-2,3,7,g-TCDD: , 1.6ng 13.'r' <-12- 1,2,3,4,7-PeCDD: 4iig “’Ci; 1,2,3,4,6,-PeCDF: 4ng ”Ci2-1,2,3,4,6,9-HxCDF: 4ng o *’C,rl,2,3,4,6,8,9-HpCDF: 4ng H *^^Field duplicates may not be consistently collected at a frequency of 1 /week during Phases T and TT as the location selected for analysis will be dictated by PMio measurements. 14 *^^Will be collected at a frequency of l/day; during Phase I and II only 1 field/trip blank per week will be analyzed. I to Reanalyze: refers to reanalysis of same extract. s O o o I o o co

Cn

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000447080Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000449908

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 7, 2005.

Similar indexed content

NYC-WTC_000447891

QA plan for ambient air monitoring at 130 Liberty Street, Sept 7, 2005.

Similar indexed content

NYC-WTC_000443239

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, LMDC.

Similar indexed content

NYC-WTC_000444248

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 2005.

Similar indexed content

Compare copies and versions →