NYC-WTC_000434544
Scope of work for interior cleaning and asbestos monitoring at 125 Cedar Street.
15 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗New York DEP scope-of-work document for 125 Cedar Street remediation.
NYC-WTC_000445849–000445853OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
rate of flow, and required volumes to achieve the necessary analytical sensitivity.
4. Sampling equipment shall be placed at representative locations and away from obstruction. Sampling cassette must be placed on a tripod and not taped to existing surfaces. All air sampling equipment shall be pre- and post- calibrated to insure accurate air sampling volumes.
5. The Air Sampling Technician shall perform clearance air sampling after the areas are free of dust accumulations as determined by the Project Monitor. All surfaces must be completely dry prior to the start of sampling. Clearance air sampling shall be performed at each apartment. Five samples shall be collected in each apartment and two samples shall be collected in each common space. The elevator shaft and first floor commercial spaces shall be cleared separately. Clearance air monitoring shall be performed after the completion of all clean up activities at the work site. Clearance air sampling shall be aggressive and performed in accordance with Title 15, Chapter 1 of the RCNY Section 1-43 (a)-(d).
6. Clearance air samples shah be collected in accordance with the procedures specified in the NIOSH 7400 Method. The flow rate for collection of air samples shall be at least 10 liters per minute and no more than 15 liters per minute. Air sampling cassettes must be monitored to ensure the filters do not develop dark spots that would indicate clogging. The minimum sampling volume is 3600 liters. If clogging develops, the cassette must be changed.
7. All clearance air samples and completed chain of custody forms must be transported to the laboratory immediately after sampling is completed.
Clearance Criteria
1. The following clearance levels have been established by the USEPA for clean up activities resulting from the collapse of the WTC.
Parameter Clearance Level Note__________________ Asbestos in air 0.0009 f/cc PCMe Primary clearance level Lead in settled dust <25 qg/fri___________ Primary clearance level Dioxin in settled dust <4ng/m^____________ Primary clearance level Fibrous glass in air <0.01 f/cc Secondary clearance level Crystalline silica in air 0.5gg/m^____________ Secondary clearance level PAHs in settled dust <0.3 mg/m Secondary clearance level Mercury between 1 and 2 mg/m‘ Secondary clearance level
2. Cleaning shall not be considered compete unless the primary clearance levels are achieved. The apartment will be re-cleaned and retested if the primary clearance levels are not achieved. These clearance levels may be re-evaluated and revised if determined necessary based on field conditions and analytical limitations. Secondary clearance levels shall be considered in determining the need for additional cleanup, however failure to meet the secondary clearance levels does not automatically trigger the re-cleaning.
4 of 5
CITY_21MC100_0 04998693
NYC-WTC_000445852
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000434544
Scope of work for interior cleaning and asbestos monitoring at 125 Cedar Street.
15 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434571
Duplicate scope of work for interior cleaning and asbestos monitoring at 125 Cedar Street.
15 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000441311
Scope of work for asbestos sampling and air monitoring at 125 Cedar Street.
15 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000442087
DEP scope of work for asbestos interior cleaning and monitoring at 125 Cedar Street.
15 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000447374
Chain-of-custody style scope of work for 125 Cedar Street asbestos cleanup monitoring.
15 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000441728
Scope of work for asbestos abatement monitoring and clearance sampling.
15 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000442641
Scope of work for asbestos surface monitoring and interior cleaning oversight at 125 Cedar Street.
15 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000430690
Follow-up scope for environmental sampling and asbestos monitoring at 125 Cedar Street.
15 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000435224
Scope for on-site asbestos air monitoring during interior cleaning at 125 Cedar Street.
15 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000444042
Chain-of-custody scope of work for asbestos air monitoring and debris cleanup at 125 Cedar Street.
15 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000455813
Scope of work for monitoring and cleanup of 125 Cedar Street interior; asbestos sampling included.
15 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000430681
Scope of work for asbestos cleaning and monitoring at 125 Cedar Street.
15 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000434544
Scope of work for interior cleaning and asbestos monitoring at 125 Cedar Street.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434571
Duplicate scope of work for interior cleaning and asbestos monitoring at 125 Cedar Street.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000441311
Scope of work for asbestos sampling and air monitoring at 125 Cedar Street.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000435224
Scope for on-site asbestos air monitoring during interior cleaning at 125 Cedar Street.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000430690
Follow-up scope for environmental sampling and asbestos monitoring at 125 Cedar Street.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000442641
Scope of work for asbestos surface monitoring and interior cleaning oversight at 125 Cedar Street.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000434544
Scope of work for interior cleaning and asbestos monitoring at 125 Cedar Street.
Similar indexed content
NYC-WTC_000434571
Duplicate scope of work for interior cleaning and asbestos monitoring at 125 Cedar Street.
Similar indexed content
NYC-WTC_000441311
Scope of work for asbestos sampling and air monitoring at 125 Cedar Street.
Similar indexed content
NYC-WTC_000442087
DEP scope of work for asbestos interior cleaning and monitoring at 125 Cedar Street.
Similar indexed content
NYC-WTC_000447374
Chain-of-custody style scope of work for 125 Cedar Street asbestos cleanup monitoring.
Similar indexed content