ASBESTOS and OTHER FIBERS by PCM: METHOD 7400, Issue 2, dated 15 August 1994 - Page 11 of 15

The curves in Figures 1 are defined by the following equations:

UCL = 2 X + 2.25 + [(2.25 + 2 X)^ - 4 ( 1 - 2.25 S,^) X=]^'^ (3) 2(1- 2.25 S,^)

LCL - 2 X - 4 [(4 - 2 X )’ 4 ( 1 - 4 ) X= (4) 2 ( 1 - 4 S," )

where S, = subjective interlaboratory relative standard deviation, which is close to the total interlaboratory S when approximately 100 fibers are counted. X= total fibers counted on sample LCL = lower 95% confidence limit. UCL = upper 95% confidence limit. Note that the range between these two limits represents 90% of the total range.

REFERENCES:

[1] Leidel, N. A., S. G. Bayer, R. D. Zumwalde, and K. A. Busch. USPHS/NIOSH Membrane Filter Method for Evaluating Airborne Asbestos Fibers, U.S. Department of Health, Education, and Welfare, Publ. (NIOSH) 79-127 (1979). [2] Baron, P. A. and G. C. Pickford. "An Asbestos Sample Filter Clearing Procedure," Appl. Ind. Hyg.., 1:169-171, 199 (1986). [3] Occupational Safety and Health Administration, U.S. Department of Labor, Occupational Exposure to Asbestos, Tremolite, Anthophyllite, and Actinolite Asbestos; Final Rules, 29 CFR Part 1910.1001 Amended June 20, 1986. [4] Rooker, S. J., N. P. Vaughn, and J. M. LeGuen. "On the Visibility of Fibers by Phase Contrast Microscopy," Amer, hd. Hyg. Assoc. J., 43, 505-515 (1982). [5] Baron, P. and G. Deye, "Electrostatic Effects in Asbestos Sampling," Parts I and II Amen Ind. Hvo. Assoc. J., 51, 51-69 (1990). [6] Johnston, A. M., A. D. Jones, and J. H. Vincent. "The Influence of External Aerodynamic Factors on the Measurement of the Airborne Concentration of Asbestos Fibers by the Membrane Filter Method," Ann. Occufi. Hvo.. 25, 309-316 (1982). [7] Beckett, S.T., "The Effects of Sampling Practice on the Measured Concentration of Airborne Asbestos," Ann- Qccua. Hvo.. 21, 259-272 (1980). [8] Jankovic, J. T., W. Jones, and J. Clere. "Field Techniques for Clearing Cellulose Ester Filters Used in Asbestos Sampling," Appi. Jnd. Hvo.. 1, 145-147 (1986). [9] Crawford, N. P., H. L. Thorpe, and W. Alexander. "A Comparison of the Effects of Different Counting Rules and Aspect Ratios on the Level and Reproducibility of Asbestos Fiber Counts," Part I: Effects on Level (Report No. TM/82/23), Part II: Effects on Reproducibility (Report No. TM/82/24), Institute of Occupational Medicine, Edinburgh, Scotland (December, 1982). [10] NIOSH Manual of Analytical Methods, 2nd ed.. Vol. 1., P&CAM 239, U.S. Department of Health, Education, and Welfare, Publ. (NIOSH) 77-157-A (1977). [11] Revised Recommended Asbestos Standard, U.S. Department of Health, Education, and Welfare, Publ. (NIOSH) 77-169 (1976); as amended in NIOSH statement at OSHA Public Hearing, June 21,1984. [12] Asbestos International Association, AIA Health and Safety Recommended Technical Method #1 (RTMI). "Airborne Asbestos Fiber Concentrations at Workplaces by Light Microscopy" (Membrane Filter Method), London (1979). [13] Abell, M., S. Shulman and P. Baron. The Quality of Fiber Count Data, Appl. Ind. Hyg.. 4, 273- 285 (1989).

NIOSH Manual of Analytical Methods (NMAM), Fourth Edition, 8/15/94

CITY_21MC100_003230538

NYC-WTC_000445735

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000445735Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →