NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 100 pages

Part 763 Asbestos – EPA SOP excerpt

Machine-extracted title · confidence 46%

EPA Part 763 subpart I excerpt regarding asbestos, testing parameters and definitions.

NYC-WTC_000445234–000445333
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Environmental Protection Agency Pt. 763, Subpt. E. App. E background on each side of the peak for one- the aliquot to the reservoir. Keep the tip of half the peak-scanning time. The net inten­ the pipet near the surface of the isopropanol. sity, la, is the difference between the peak Filler rapidly under vacuum. Do not wash integrated count and the total background the sides of the reservoir. Leave the vacuum count. on for a time sufficient Lo dry the filter. Re­ 13. Determine the net count, lAg, of the fil- lease the vacuum and remove the filler with tei‘ 2.36 A silver peak following the procedure forceps. in step 12. Remove the filter from the holder, reverse it, and reattach it to the holder. De­ 2.8.2 Analysis of Calibration Standards termine the net count for the unattenuated 1. Mount each filter on a flat holder. Per­ silver peak, I^g. Scan times may be less for form step scans on selected diagnostic reflec­ measurement of silver peaks than for sample tions of the standards and reference speci­ peaks; however, they should be constant men using the procedure outlined in Section throughout the analysis. 2.7.2.3, step 12, and the same conditions as 14. Normalize all raw, net intensities (to those used for the samples. correct for instrument instabilities) by ref- 2. Determine the normalized intensity for erencing°them to an external standard (e.g., each peak measured, Igtd, as outlined in Sec­ the 3.34 A peak of an Ct-quartz reference crys­ tion 2.7.2.3, step 14. tal). After each unknown is scanned, deter­ mine the net count, Ir, of the reference speci­ 2.9 Calculations men following the procedure in step 12. De­ termine the normalized intensities by divid­ For each asbestos reference material, cal­ ing the peak intensities by U: culate the exact weight deposited on each standard filter from the concentrations of the standard suspensions and aliquot vol­ umes. Record the weight, w, of each stand­ Ag JO Ag JO ard.-Prepare a calibration curve by regress­ I? ing I2^td on w. Poor reproducibility (±15 per­ cent RSD) at any given level indicates prob­ 2.8 Calibration lems in the sample preparation technique, and a need for new standards. The data 2.8.1 Preparation of Calibration Standards should fit a straight line equation. 1 . Mill and size standard asbestos materials Determine the slope, m, of the calibration according to the procedure outlined in Sec­ curve in counts/microgram. The intercept, b, tion 2.7.2.1.1. Equivalent, standardized matrix of the line with the Istd axis should be ap­ reduction and sizing techniques should be used proximately zero. A large negative intercept for both standard and sample materials. indicates an error in determining the back­ 2. Dry at 100 °C for 2 hr; cool in a desic­ ground. This may arise from incorrectly cator. measuring the baseline or from interference 3. Prepare two suspensions of each stand­ by another phase at the angle of background ard in isopropanol by weighing approxi­ measurement. A large positive intercept in­ mately 10 and 50 mg of the dry material to dicates an error in determining the baseline the nearest 0.01 mg. Quantitatively transfer or that an impurity is included in the meas­ each to a 1—L volumetric flask with approxi­ ured peak. mately 200 mL isopropanol to which a few Using the normalized intensity, I^g, for the drops of surfactant have been added. attenuated silver peak of a sample, and the 4. Ultrasonicate for 10 min at a power den­ corresponding normalized intensity from the sity of approximately 0.1 W/mU, to disperse unattenuated silver peak, lAg, of the sample the asbestos material. filter, calculate the transmittance, T, for 5. Dilute to volume with isopropanol. each sample as follows:26 27 6. Place the flask on a magnetic stirring plate. Stir. 7. Prepare, in triplicate, a series of at least five standard filters to cover the desired ana­ lytical range, using appropriate aliquots of ^Aq the 10 and 50 mg/L suspensions and the fol­ lowing procedure. T = Mount a silver membrane filter on the fil­ 1° tration apparatus. Place a few milliliters of isopropanol in the reservoir. Vigorously Ag hand shake the asbestos suspension and im­ Determine the correction factor, f(T), for mediately withdraw an aliquot from the cen­ each sample according to the formula: ter of the suspension. Do not adjust the vol­ -R (In T) ume in the pipet by expelling part of the sus­ pension; if more than the desired aliquot is f(T)=----------- l-TR withdrawn, discard the aliquot and resume the procedure with a clean pipet. Transfer where

737

CITY_21MC100_011986033

NYC-WTC_000445322

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000445322Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000442707

Pallet of Part 763 asbestos-related standard references and definitions.

Similar indexed content

Compare copies and versions →