NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 100 pages

Part 763 Asbestos – EPA SOP excerpt

Machine-extracted title · confidence 46%

EPA Part 763 subpart I excerpt regarding asbestos, testing parameters and definitions.

NYC-WTC_000445234–000445333
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Environmental Protection Agency Pt. 763, Subpt. E. App. A Shrink fit gel-bands may be used for this d. Check the sampling system for leaks purpose and are available from filter manu­ with the end cap still in place and the pump facturers and their authorized distributors. operating before initiating sample collec­ j. Use wrinkle-free loaded cassettes in the tion. Trace and stop the source of any flow sampling operation. indicated by the flowmeter under these con­ 5. Pump setup. ditions. a. Calibrate the sampling pump over the e. Select an appropriate flow rate equal to range of flow rates and loads anticipated for or greater than 1 L/min or less than 10 L/min the monitoring period with this flow meas­ for 25 mm cassettes. Larger filters may be uring device in series. Perform this calibra­ operated at proportionally higher flow rates. tion using guidance from EPA Method 2A f. Orient the cassette downward at approxi­ each time the unit is sent to the field (See Reference 6 of Unit III.L.). mately 45 degrees from the horizontal. b. Configure the sampling system to pre­ g. Maintain a log of all pertinent sampling clude pump vibrations from being trans­ information, such as pump identification mitted to the cassette by using a sampling number, calibration data, sample location, stand separate from the pump station and date, sample identification number, flow making connections with flexible tubing. rates at the beginning, middle, and end, start c. Maintain continuous smooth flow condi­ and stop times, and other useful information tions by damping out any pump action fluc­ or comments. Use of a sampling log form is tuations if necessary. recommended. See the following Figure 2:

683

CITY_21MC100_011985979

NYC-WTC_000445268

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000445268Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000442707

Pallet of Part 763 asbestos-related standard references and definitions.

Similar indexed content

Compare copies and versions →