2.0 SAMPLING SITES 2.1 Network Design

Due to the unique circumstances associated with this deconstruction project three different types of monitoring sites are recommended for inclusion in the active monitoring network as follows:

• On-Site Street Level Stations- These locations essentially represent sidewalk settings situated around the perimeter of the building. Four (4) such stations will be included in the monitoring network as shown in Figure 1.

• Off-Site Elevated Stations- While extremely unlikely, it is not impossible for dusts to be released during building deconstruction at upper levels of the 40-story structure. Accordingly, the proposed network will make use of monitoring sites in place at elevated locations above street level. It is EMDC’s intention to include three (3) to four (4) such stations in the monitoring network. Three (3) of the proposed off-site rooftop sampling locations under consideration are identified in Figure 2.

• On-Site Scaffolding Elevated Stations- Air monitoring stations will also be located on the four sides of the scaffolding. These four “floating” monitoring stations will be re-located on the scaffolding in ten floor increments as the abatement and demolition work progresses from the roof level to ground level. Four (4) such stations will be included in the monitoring network (one on each side of the scaffolding) as shown in Figure 2.

2.2 Siting Criteria and Network Operations

The proposed full network will be comprised of up to twelve (12) stations in simultaneous operation at all times that building deconstruction activities are in progress, four (4) street level, three (3) to four (4) off-site elevated, and four (4) on the scaffolding. The placement of sampling stations will follow USEPA and United States Army Corps of Engineers (ACOE) siting criteria for ambient particulate sampling systems to the extent possible. Strict adherence to these criteria at all stations may not be possible given the topography and logistics of the urbanized environment characteristic of the Eower Manhattan setting.

All of the stations will communicate with a central computer housed in the site vicinity. These on-site stations will collect data continuously and telemeter (wirelessly transmit) the data to the central computer. All of the monitoring stations in the immediate vicinity of the deconstimction site will monitor particulate as PMio and PM2.5 on a real-time basis. These data will be logged continuously at each of the sites as well as on the data logger contained in the on site computer center. These data will be stored and archived as 10-minute averages for each of the stations.

L2005-149 (081205)v2 2-1 5023623.2

CITY_21MC100_0 03239268

NYC-WTC_000445090

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000445090Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000427190

Chain-of-custody for August 2005 ambient air monitoring at 130 Liberty Street deconstruction site, LMDC.

Similar indexed content

Compare copies and versions →