Part V - Quality Assurance Project Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701 - November 4, 2005

Mercury (Gaseous) Using an Ohio Lumex RA915+ Mercury Analyzer Table 13-3b summarizes the calibration procedures associated with the mercury (gaseous) analysis using the Ohio Lumex RA915+ Mercury Analyzer.

Table 13-3b. Calibration Requirements for the Ohio Lumex RA915 -h Mercury Analyzer Equipment Activity Acceptance Criteria Corrective Action Ohio Lumex Factory calibration NA NA RA915+ prior to purchasing unit and when unit continuously fails operating specifications Calibration ±20% of true value Perform verification: maintenance and/or performed prior to consult and after each manufacturer sampling event (placed in Test mode, internal test cell containing mercury vapor placed in optical path of instrument) records of calibrations maintained by Quality Assurance Officer.

Asbestos Mercury, Silica and PCBs using a Personal Sampling Pump A primary cell calibrator will be used to calibrate field sampling pumps. Calibration information (i.e., date, times, equipment make/model/serial number, and results of calibration) will be recorded in calibration logbooks. Flow Rate Calibration - Prior to first use, or in the event that the sampling pump fails the flow rate verification, the flow rate on the pump will be calibrated by setting the flow rate to the respective set points using a suitable flow­ measuring device that is NIST traceable.

PCDDs/PCDFs and PAHs using a PS-1 High Volume Sampler The initial calibration of the PS-1 sampler will be performed using a critical orifice serving as a reference standard in concert with a water manometer. The critical orifice calibration will be performed by the manufacturer (Tisch) and is NIST traceable. The sampler will be calibrated on-site using a certified flow orifice device before and after each sample collection period to determine volumetric flow rates. All calibration measurements will be standardized to 760 mm Hg and 25oC. Table 13-3c summarizes the calibration procedures associated with the PS-1 samplers.

95

CITY_21MC100_007120813

NYC-WTC_000444590

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000444590Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000441133

Plan for Environmental Community Air Monitoring at Greenwich/Thames sites, Nov 2005.

Similar indexed content

NYC-WTC_000441316

Plan for Environmental Community Air Monitoring at Greenwich Street and Thames Street sites, Nov 2005.

Similar indexed content

NYC-WTC_000453085

Plan for Greenwich Street and Thames Street monitoring within WTC-related cleanup.

Similar indexed content

NYC-WTC_000446622

Part V plan for Environmental Community Air Monitoring at Greenwich/Thames sites.

Similar indexed content

Compare copies and versions →